USER GUIDE – v2.1
ID:
5929745
7
|
DMX USB Pro Mk2 (70314)
Visit the ENTTEC
website
for the latest version
Devices
Once the DMX USB PRO Mk2 is connected to PRO-Manager, the Devices tab gives a quick overview of the
selected device.
This will display:
Devices Serial Number
Devices Firmware version
Device Type
Device Capability
Firmware Update
Firmware update
The Firmware update procedure can be used to:
Update to the latest feature set.
Reset DMX USB PRO Mk2 if it ever gets stuck or stops responding. (error mode).
The following steps will explain the firmware update procedure:
3.
Within PRO-Manager Device Tab, at the bottom of the screen is a drop down to select a default firmware
option, or download a version from the ENTTEC website and locate it manually with ‘Choose File’.
4.
After selecting the firmware file, click on the “Update Firmware” button and let the update proceed. Do
not remove the USB until the update is complete. The update progress is displayed on the webpage.
5.
Once Finished, the page will automatically refresh, and device information will be updated to reflect the
updated firmware.
Settings
Once the DMX USB PRO MK2 is connected to PRO-Manager, the Settings tab allows the adjustment of the
DMX output parameters to accommodate for equipment that fall outside of the USITT DMX512-A standard.
The following parameters can be adjusted:
DMX Output Refresh Rate (per sec): This can be set between 0 and 40.
40 is the Default
DMX Output Mark After Break (MAB in µsec): This can be set between 10 and 1355.
10 is the Default
Break Time (µsec): This can be set between 96 and 1355.
96 is the Default