CONTENTS

1. Parts and Functions

Touch Sensitive

Digital Keypad

Nameplate

Call Button

Microphone

Rainy Guard

Side View

90mm

176mm

23mm

Rainy Guard

Side View

Camera Lens

Touch Sensitive

Digital Keypad

Speaker

Nameplate

Call Button

Microphone

119mm

220mm

Screws for panel 

mounting

1.1 Door Station E

1.2 Door Station F

1. Parts and Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
2. Mounting and Setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
     2.1  Door station Mounting - - - - - - - - - - - - - - - - - - - - - - - - 2
3. Terminal Descriptions - - - - - - - - - - - - - - - - - - - - - - - - - - -  5
4. System Wiring and Connections - - - - - - - - - - - - - - - - - - - - 6
     4.1 Basic Connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
     4.2 Electric Lock Connection - - - - - - - - - - - - - - - - - - - - - - - 6
     4.3 Electromagnetic Lock Connection - - - - - - - - - - - - - - - - - 7
     4.4 Multi Door Stations Connection - - - - - - - - - - - - - - - - - - - 9
     4.5 Multi Monitors Connection - - - - - - - - - - - - - - - - - - - - - - 10
5. DIP Switches Setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -11
     5.1 DIP Switches Settings of Doorstation - - - - - - - - - - - - - - -11
     5.2 DIP Switches Settings of Monitor - - - - - - - - - - - - - - - - - -11
6. ID Card Registration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12
     6.1 Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
     6.2 Add User Cards - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12
7. Unlock Operations - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14
     7.1 Unlocking user code - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14
8. Precaustions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
9. Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15

Summary of Contents for 13535

Page 1: ...The design and specifications can be changed without notice to users Copyright of this manual is reserved VIDEO DOOR PHONE SYSTEM USER MANUAL English Item No 13535 13536 Version2 0 1 1 12 01 ...

Page 2: ...Functions 1 2 Mounting and Setting 2 2 1 Door station Mounting 2 3 Terminal Descriptions 5 4 System Wiring and Connections 6 4 1 Basic Connection 6 4 2 Electric Lock Connection 6 4 3 Electromagnetic Lock Connection 7 4 4 Multi Door Stations Connection 9 4 5 Multi Monitors Connection 10 5 DIP Switches Setting 11 5 1 DIP Switches Settings of Doorstation 11 5 2 DIP Switches Settings of Monitor 11 6 I...

Page 3: ...ttach the panel to the rainy guard Use the screwdriver and the screw to fix the panel Connect the cable correctly and adjust camera to the right angle Adjust camera angle 1 2 4 3 Drill holes in the wall to match the size of the mounting box and attach it to the wall Attach the panel to the mounting box and use supplied screws to fix the panel Place name label Connect the cable correctly and adjust c...

Page 4: ...c locks BUS Connect to the bus line no polarity PL External lock power input connect to the power positive power S1 S2 Lock power output to connect 2 locks S Lock power output connect to the power input of locks only when using the camera to power the locks if using the external power supply for the locks the S should not be connected 2 3 Adjusting Camera Angle 2 2 Placing Name Label Move the plas...

Page 5: ...s limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default 4 3 1 Door Lock Controlled by Internal Power Connect one lock Jumper position in 2 3 1 2 3 EB LOCK BUS PL S1 S2 S Normally closed Connect two lock Jumper position in 2 3 EB LOCK LOCK 2nd 1ST 2nd EB 1ST 1 2 3 BUS PL ...

Page 6: ...LOCK button and hold for 2s 6 Setting unlock mode to 0 or 1 3 The default password is 2008 9 8 4 3 3 Unlock parameter setting set in monitor 4 4 Multi Door Stations Connection Note 1 Must connect DT596 correctly before setting 2 The parameter will be saved in DT596 automatically so you only need to set one monitor 3 The above cutline is fit for T107 series monitors only for T753 T863 series monitor...

Page 7: ...ay 2 terminal doesn t respond to the second lock and will be closed for 60 seconds when the Lockout is carried out The alarm connected to the terminal of relay 2 will be activated inactivate Reserve There are 6 bit switches in total The DIP switches are used to configure the User Code for each Monitor Bit 6 is line terminal switch which needs to be set to ON if the Monitor is in the end of the bus ...

Page 8: ... CARD ADD card to ID card window in standby mode beep beep red on off blue Show the MASTER CARD ADD card to exit But it will return to standby mode if no operation within 15s beep beep red off off blue Show user cards to be added one by one beep red blink off blue 6 2 2 Control two lock Show the MASTER CARD ADD card to ID card window in standby mode beep beep red on off blue Show the MASTER CARD ADD ca...

Page 9: ...s can be authorized to master cards when registered new master cards the old master cards will be invalid automatically 7 Unlock Operations When the registered user card has been shown to ID card window the LED indicator the first lock red the second lock blue lights up the buzzer sounds and the electric door strike will be unlocked Note 1 if the user card controls one lock only show the user card ...

Reviews: