Pairing Secure Lock Relay with Call Panel
9
7
Pairing Secure Lock Relay with Call Panel
Confirm Door No. of Call Panel
i.
Connect a laptop or PC to the same network as the Call Panel.
ii.
Use a web browser and enter the IP address of the Call Panel in to the address bar.
iii.
Login to the call panel using the username
admin
and the device admin password.
iv.
Navigate to Local Settings > Basic.
v.
Check the
Door No.
- each Call Panel on a block should have a unique number.
FIGURE 7-1
Secure Lock Relay RS485 Address
•
Each Secure Lock Relay must have the address corresponding to the last 2 digits within the Door
No. of the associated Call Panel.
o
E.g. Door No. 80
01
= RS485 address
1
. Door No. 80
15
= RS485 address
15
.
•
SW1 Switches 1-6 set the binary address (0-63).
Switch
1
2
3
4
5
6
Binary Value
1
2
4
8
16
32
Address 0
0
0
0
0
0
0
Address 1
1
0
0
0
0
0
Address 3
1
1
0
0
0
0
Address 7
1
1
1
0
0
0
Address 15
1
1
1
1
0
0
Address 31
1
1
1
1
1
0
Address 63
1
1
1
1
1
1
FIGURE 7-2 - BINARY ADDRESS TABLE
ON = 1
OFF = 0