Call Panel Splitter

 

8

 

 

5

 

Call Panel Splitter

 

 
 

 

 
 

FIGURE 5-1

 

 

6

 

Call Panel Connections

 

 

 

FIGURE 6-1

 

 

Connection

 

Cable Type

 

Detail

 

 

RS485 from Call Panel Splitter

 

1x Cat5e or Cat6

 

1 Pair UTP -  RS485B

 

 

12VDC from Call Panel 
Splitter

 

1 Pair UTP - 12v (White)

 

2 Pair UTP - 0v (Black)

 

 

Ethernet to Network Switch 

 

1x Cat5e or Cat6

 

RJ45 - T568B

 

 

FIGURE 6-2 - EIA/TIA-568B COLOUR CODE

 

 

12VDC Connections to Call Panel 
12v, 0v

 

 

RS485 Data to Call Panel

 

 

FS1-FS4

 - Call Panel Supply Fuses 

(1.25 Amp Fast Acting)

 

 

PL5

 - Not Used

 

 

PL1-PL4

 - Call Panel Connection 

Plugs

 

A

 

B

 

C

 

D

 

E

 

A

 

B

 

C

 

Up to 90M

 

A

 

B

 

C

 

C

 

D

 

E

 

A

 

B

 

Summary of Contents for PRO-DC1

Page 1: ...PRO DC1 2 Installation and Setup Guide Issue 002 ...

Page 2: ...8th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS TO OTHER SERVICES imposes requirements for segregation of door entry access control circuits Band I 230VAC mains circuits Band II and other higher voltage circuits IET Wiring Regulations 18th Edition...

Page 3: ...tions 6 4 Secure Lock Relay 7 Input Exit Switch Connections 7 Fail Open Lock Connection 7 Fail Closed Lock Connection 7 Lock Suppression 7 5 Call Panel Splitter 8 6 Call Panel Connections 8 7 Pairing Secure Lock Relay with Call Panel 9 Confirm Door No of Call Panel 9 Secure Lock Relay RS485 Address 9 8 Device List 10 ...

Page 4: ...t The specification below shows the minimum cable requirements allow for extra cabling if redundancy is required Connection Cable A Door controller to each call panel 2x Cat5e or Cat6 B Lock Relay to locks 2x 1 5mm multi stranded flex or singles route through any exit fire switch or break glass for fail safe operation C Lock Relay to exit switch 1 Pair UTP 2 cores Cat5e or Cat6 D Lock Relay to fir...

Page 5: ...GURE 2 1 Item Connection Detail Power Supply Unit PSU Section 3 Page 6 Secure Lock Relay Section 4 Page 7 Secure Lock Relay PRO DC2 only Call Panel Splitter Section 5 Page 8 Network Switch Section 6 Page 8 A B C D E C B A E D ...

Page 6: ...Point Pre Wired 12V to Internal Devices Backup Battery Connections for Sealed Lead Acid Battery Output Voltage Adjustment SYSTEM VOLTAGE 13 8VDC Always test the output voltage Only adjust if required Fuse Holder Mains Supply Cable from Fused Spur 1 5mm Twin Earth LIVE BROWN NEUTRAL BLUE EARTH GREEN YELLOW Sheath A B C D E A B L N E B B L N E E A C D A ...

Page 7: ...agnetic locks FIGURE 4 2 Fail Closed Lock Connection Connection for fail closed locks power to release e g electric strike FIGURE 4 3 Lock Suppression _ Lock Secure Lock Relay FIGURE 4 4 1N4007 DIODE FITTED AT LOCK Entrotec recommend locks with built in suppression If such a lock is not being used it is ESSENTIAL to fit suitable suppression as close to the lock as possible This prevents back EMF a...

Page 8: ...485A RS485B 12VDC from Call Panel Splitter 1 Pair UTP 12v White 2 Pair UTP 0v Black Ethernet to Network Switch 1x Cat5e or Cat6 RJ45 T568B FIGURE 6 2 EIA TIA 568B COLOUR CODE 12VDC Connections to Call Panel 12v 0v RS485 Data to Call Panel FS1 FS4 Call Panel Supply Fuses 1 25 Amp Fast Acting PL5 Not Used PL1 PL4 Call Panel Connection Plugs A B C D E A B C Up to 90M A B C C D E A B ...

Page 9: ... the Door No each Call Panel on a block should have a unique number FIGURE 7 1 Secure Lock Relay RS485 Address Each Secure Lock Relay must have the address corresponding to the last 2 digits within the Door No of the associated Call Panel o E g Door No 8001 RS485 address 1 Door No 8015 RS485 address 15 SW1 Switches 1 6 set the binary address 0 63 Switch 1 2 3 4 5 6 Binary Value 1 2 4 8 16 32 Addre...

Page 10: ...Device List 10 8 Device List IP Address Block ID SIP ID Type Description 192 168 1 111 1 8001 Call Panel Ashwood Court Front Door ...

Page 11: ...Notes 11 ...