Summary of Contents for EM EMSW

Page 1: ...Swing Door Operator EM EMSW User Manual Original instructions...

Page 2: ...10 Safety accessories 10 Troubleshooting 11 Service Maintenance 11 Other products from Entrematic Group 12 Declaration of conformity All rights in and to this material are the sole property of Entrem...

Page 3: ...rs of age if they have been instructed by a person in charge of their safety The operator can be used by children 8 years of age or younger if they are supervised by a person respons ible for their sa...

Page 4: ...er is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the receiver with respect to the equipment Move the receiver away...

Page 5: ...led indoors where it is suitable for almost all types of external and internal swing doors This widely used operator can be found on applications ranging from handicapped access in private homes to hi...

Page 6: ...PEN TIME HOT When the HOT has elapsed the door will close The EM EMSW can be set in three different modes if a programme selector is installed see picture below In fully manual use or in case of a pow...

Page 7: ...the door Activate the manual activation units if any and walk towards the door Check that the door has opened appropriately while you pass the entrance exit Then proceed with the automatic activation...

Page 8: ...be documented To avoid damages to the profiles the brushes weather stripping must be vacuum cleaned weekly Do not expose windows doors or profiles to alkalis Both aluminium and glass are sensitive to...

Page 9: ...d to all glass sections that are moving Supervision of child applied to both sides of the door Mandatory according to national regulations Recommended if the risk analysis shows use by children Operat...

Page 10: ...ection see page 8 Troubleshooting Remedies What s wrong The door does not open Change the setting of the mode selector See page 6 The motor does not start Check that there are no objects in the detect...

Page 11: ...onment Cycles hour in operation Part number Part 100 100 10 High traffic Medium traffic Low traffic 6 6 12 24 331003882 Vibration absorbers and oil plug 6 6 12 24 330000485BK SI PUSH PUSH 335 service...

Page 12: ...applied BVL BBR UL 325 FCC 47 CFR Part 15 B IEC 60335 2 103 2002 ed 1 2011 ed 2 1 IEC 60335 1 2010 ed 5 EN 1634 1 2008 DIN 18650 1 2 2010 IEC 60950 1 2005 ed 2 ECtypeexaminationorcertificateissuedbya...

Page 13: ......

Page 14: ...Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden Tel 46 10 47 48 300 www entrematic com info em entrematic com...