4
IP2176 - 2017-03-17
The tests carried out in the laboratory and onsite indicate a maximum load of the mobile wing as shown in the
diagram 1.
In the sections below, the used formulas take into account the following standard criteria:
- the PLmax maximum door width is considered to be between the uprights of the fixed doors and/or the frame.
The effective passage opening has a tolerance of ±20 mm.
- for every type of door, the reference dimension of the automation is indicated (LT).
N.B.: The ALU48SBO system, with sliding door wings, only allows break-out of the door wings when they are
closed.
2. Operating
instructions
1. General safety precautions
This installation manual is intended for qualified personnel only.
Read the instructions carefully before installing the product. Bad installation could be dangerous.
Before installing the product, make sure it is in perfect condition. Use original spare parts only for repairs or replacements of products.
These instruction must be kept and forwarded to all possible future users of the system.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as these are a potential source of danger.
The ALU48 door frame system complies with the essential requirements of the following standards:
EN 16005 European Standard - Safety in use of power operated pedestrian door sets
Standard DIN 18650-1 - Standard DIN 18650-2
Drawings of all standard typologies are available in graphic format for CAD environments (dwg or dxf) and
image format (pdf) at http://www.ditecentrematic.com/download.
Sliding door made with EN AW 6060 T5 (UNI 9006/1) aluminium alloy extruded profiles
- 48 mm size
– suitable for DITEC automated installations, with special devices that guarantee accident prevention
- surface finish with powder coating (polyester powder in RAL colours- Qualicoat) or anodising (EURAS finishes - Qualanod).
The profile series is equipped with snap-on glazing retainers to house 8, 10, 22, 40 mm thick glass provided for safe anchoring of the glass and correct adjustment during installation. The system
also allows maintenance to be carried out easily if glasses are accidentally damaged or broken.
The door frame is equipped with special EPDM gaskets for the hermetic central stop with brush-type seals in the openable horizontal and vertical perimeters which give the system optimal
temperature and sound proofing performances.
The door frames are designed in a wide range of coded typologies to allow customers to select a solution that suits the type of installation according to the specifications in the Technical Manuals.
The ALU48 series consists of profiles (uprights and crosspieces) with sturdy visible sections.
Profiles are designed to house locks with European cylinder for moving wing closure (night-time closure), available with an additional floor lock too.
3. Entrance/exit door frame – Ditec ALU48 Series
i
This symbol indicates instructions or notes regarding safety, to which special attention must be paid.
This symbol indicates useful information for the correct functioning of the product.
EN
i
For dimensions and/or weights which are not accounted for in the diagram, confirm the feasibility of the project with
our technical-commercial offices.
600 800
0
0
80
100
120
20
40
60
VALOR L-P / REX S
VALOR N
VALOR N
1000 1200
mm
1400
max
kg
0
80+80
20+20
40+40
60+60
100+100
120+120
90+90
70+70
REX S
VALOR L-P
Diagram 1 - Mobile wing’s weight limit
Summary of Contents for Ditec ALU48RBO
Page 48: ...48 MH 70 9803 9809 9803 90 Out of scale T39 IP2176 2017 03 17 90 M 17 Technical sections ...
Page 57: ...57 MH 70 9803 9809 9803 100 M 100 Out of scale T48 IP2176 2017 03 17 17 Technical sections ...
Page 86: ...86 20 Working operations 9821 NOTE 2 see page 10 L90 113 Ø12 Ø6 T77 IP2176 2017 03 17 ...
Page 93: ...93 20 Working operations 60 1118 25 G01 9829 T84 IP2176 2017 03 17 ...