![EntraPass E-PASS-21W Installation & Programming Instructions Download Page 3](http://html.mh-extra.com/html/entrapass/e-pass-21w/e-pass-21w_installation-and-programming-instructions_2415140003.webp)
COMPONENT LOCATIONS
RED/GREEN
POWER/ACCESS
INDICATOR
YELLOW
"LOCKOUT"
INDICATOR
MASTER CODE
RESET JUMPER
(JP2)
BEZEL
TERMINAL
BLOCK #2
(TB2)
FACEPLATE
SOLID STATE
WHITE LED
DOWN LIGHT
TERMINAL
BLOCK #1
(TB1)
KEYPAD
MOUNTING
PLATE
BEEPER
LEVEL
JUMPER (JP1)
Figure 1. Component Locations
WIRING DIAGRAM
TYPICAL DOOR INSTALLATION WIRING
POWER
SUPPLY
TERMINAL
BLOCK 2
1 - AC OR DC
2 - AC OR DC
AK-21W TERMINALS
12-24 VOLT
AC OR DC
POWER
TERMINAL
BLOCK 1
SENSE - 8
COM- 7
N.C. DOOR
SWITCH
ELECTRIC
DOOR
STRIKE
3 - N.O.
4 - COM
5 - N.C.
6 - N.O.
MAIN RELAY
5 AMPS @
28 VDC MAX.
AUXILIARY
REQUEST-TO-EXIT - 6
EARTH GROUND - 5
OUTPUT #3 COM- 4
OUTPUT #3 - 3
AUXILIARY
OUTPUTS
REQUEST
TO EXIT
BUTTON
TO ALARM
SYSTEM
ALARM
CONTACT
7 - COM
RELAY 1 AMP
8 - N.C.
@28 VDC MAX.
OUTPUT #4 - 2
OUTPUT #4 COM- 1
100 mA MAX.
TO COMMON
GROUND
STAKE
REQUIRED WIRING
OPTIONAL WIRING
OTHER WIRING
NOTES:
1. ALARMSHUNT SET FOR AUXILIARY RELAY
2. TERMINAL BLOCK #2, TERMINAL 8 SET FOR DOOR SENSE
CAUTION
IF THE UNIT IS AC POWERED,
MAKE SURE THE SECONDARY OF THE
SYSTEM TRANSFORMER IS ISOLATED
FROM EARTH GROUND
Figure 2. Wiring Diagram
1
wwww.EntraPASS.com
8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]