EntraGuard

®

 Platinum Telephone Entry Controller

Installation Guide

Page 8 of 10

P/N: 01553-001 Rev. D

If the address shown as Current needs to be changed, enter the new address by pressing the numbers on the keypad. The 
number selected will show in the New line. If you enter the wrong number, simply press CLEAR to erase what has been 
entered. When you are satisfied with the address entered, press *. If you have changed the number from what is shown as 
Current, 

the controller will automatically clear the memory as it changes the address

 (see Figure 8).

Figure 8: Setting New Address

Once the memory has been cleared, the unit is ready to be configured. The LCD will display a warning that the unit has 
not been initialized. This display will rotate with the EntraGuard Default display until a Total Update from 

Doors

 has been 

performed on the unit. Once an update has been performed, only the default will be displayed.

4.2

Clear the Controller’s RAM

When turning system power on for the first time, the controller’s memory needs to be cleared of any spurious information 
that may be in the RAM. If you changed the controller address, the memory is automatically cleared. However, if you did 
not change the address, you will need to clear the controller’s RAM separately. From the Reset Menu (see Figure 6 on 
page 7), press 2 to Clear Memory. The Clear Memory screen will appear on the LCD (see Figure 9).

Figure 9: Clear Memory

From the Clear Memory Screen you may either:

1.

Press 1 to clear the controller’s RAM. The LCD will change to show the memory is being cleared (see Figure 10 on 
page 9). Once the controller’s RAM has been cleared, the unit is ready for use. The LCD will rotate between the 
Initialization Warning and EntraGuard Default screens until a Total Update from 

Doors

 has been performed on the 

unit.

OR

2.

Press 2 to return to the Reset Menu without clearing the controller’s RAM.

NOTE: Clearing the system RAM completely erases all information within the EntraGuard Platinum controller, except for 
the controller address. If there is any information in system RAM from an access control installation and the system RAM 
is cleared, the information in the controller is lost and cannot be recovered, and a Total Update must be performed.

Summary of Contents for Platinum

Page 1: ... Application Note p n 01964 001 NOTE It is the responsibility of the installation organization to have only technically qualified personnel performing the hardware installation 1 0 Drawings 1 1 EntraGuard Platinum Enclosure Figure 1 The EntraGuard Platinum Telephone Entry Controller Wiring diagrams are provided for the new style Platinum controller PCB p n 05735 001 see Figure 3 on page 3 and old ...

Page 2: ...ation Guide Page 2 of 10 P N 01553 001 Rev D 1 2 Enclosure Mounting Diagram Figure 2 Entraguard Platinum Mounting Diagram 0 00 0 552 1 553 9 686 10 235 0 00 1 001 6 892 10 888 11 223 12 48 13 808 all units in inches 0 256 dia 1 374 dia 0 386 dia 0 258 dia ...

Page 3: ...Lock Common 3 Lock NC 4 Alarm NO 5 Alarm Common 6 Alarm NC TB3 Lock Alarm Relays 1 GP1 NO 2 GP1 Common 3 GP1 NC 4 GP2 NO 5 GP2 Common 6 GP2 NC TB10 General Purpose Outputs 1 Tx Rx 2 Tx Rx 3 Shield TB1 RS 485 Network 1 12 VDC 2 Negative Ground 3 Earth Ground TB2 12 VDC Power TB15 Wired Telephone Connection 1 TIP 2 Ring J9 Standard Phone Jack Connection U39 J10 LAN Communication Jumpers Modem Module...

Page 4: ...EntraGuard Platinum Telephone Entry Controller Installation Guide Page 4 of 10 P N 01553 001 Rev D 1 4 Old Style Platinum Controller Figure 4 Old Style Entraguard Platinum Controller p n 05728 001 ...

Page 5: ...Guide Page 5 of 10 P N 01553 001 Rev D 1 5 Board Placement for a PXL 500 Controller Figure 5 Platinum Board Placement with an Optional PXL 500 Controller NOTE For information on the optional PXL 500 PXL 510 board see the PXL 500 Installation Guide P N 01530 001 ...

Page 6: ...tion between controller and host PC serial RS 232 or LAN 3 1 Serial RS 232 An RS 232 serial port connection is made by either a direct serial connection 50 feet maximum through an internal PC modem or external modem USB to serial converter uses the Direct to PC serial connection NOTE If your PC has an internal modem that modem may be prevented by the PC from properly operating with an Entraguard c...

Page 7: ...et Menu the unit must be powered up again 4 1 Set Unit Address The controller s address may only be set through the Reset Menu To set the desired operating address for the controller press 1 on the keypad The Set New Unit Address screen appears on the LCD see Figure 7 Figure 7 Set Unit Address The address range is from 1 to 128 The Master Controller must be set to address 1 Other slave EntraGuard ...

Page 8: ...ry needs to be cleared of any spurious information that may be in the RAM If you changed the controller address the memory is automatically cleared However if you did not change the address you will need to clear the controller s RAM separately From the Reset Menu see Figure 6 on page 7 press 2 to Clear Memory The Clear Memory screen will appear on the LCD see Figure 9 Figure 9 Clear Memory From t...

Page 9: ... The default is set for the large size However if the small size font would be preferred as the default it may be changed through the reset menu From the Reset Menu see Figure 6 on page 7 press 5 for LCD Setup The LCD Setup menu will appear on the LCD see Figure 11 Figure 11 Setup LCD Menu 1 Select 5 on the keypad to change the default font size The Set Font Default Menu appears see Figure 12 Figu...

Page 10: ... Contact Keri Systems end of document Keri USA Keri UK Ireland Europe 2305 Bering Drive San Jose CA 95131 Unit 17 Park Farm Industrial Estate Ermine Street Buntingford Herts SG9 9AZ UK Telephone 800 260 5265 408 435 8400 Telephone 44 0 1763 273 243 Fax 408 577 1792 Fax 44 0 1763 274 106 Web www kerisys com Web www kerisystems co uk E mail sales kerisys com techsupport kerisys com E mail sales keri...

Reviews: