22 Installation
VH-2402S
Connecting a Terminal to the Console Port
The console port is a serial RS-232 interface port that enables a
connection to a terminal for performing switch monitoring and
configuration functions. The terminal may be a PC or workstation running
terminal emulation software, or a terminal configured as a Data Terminal
Equipment (DTE) connection. Alternatively, this port can be connected to
an external modem to enable remote dial-in management. You can use
the out-of-band management program (described in the next chapter)
over a standard modem connection.
If you connect a terminal to the console port prior to powering on the
switch, you can observe the progress and results of the power-on self test
as the switch goes through its initialization process. See “Powering the
Switch” on page 25.
The console port is a standard RS-232 connection using a male DB-9
connector (see Table A-1 for pinouts). A null-modem wired RS-232 cable
is supplied with the Management Module for connecting to this interface.
This cable is shielded to comply with emissions regulations and
requirements.
Console Port (Out-of-Band) Connections
To connect the VH-2402S console port to a terminal, do the following:
1.
Connect a VT100 compatible terminal or a PC running a terminal
emulation program to the console port (Figure 2-4). Use the null-
modem cable provided with the Management Module, or use a null-
modem connection that is compatible with the console port pin
assignments shown in Appendix A.
Figure 2-4. Connecting a Terminal to the Console Port
2.
Connect one end of the interface cable directly to the Management
Module’s console port and tighten the retaining screws.