LEDs
3-4 Troubleshooting
FAN
Off
Fans are off or booting up.
None.
Green
All fans are operating normally.
None.
Amber
One fan has failed.
Replace the failed fan. See “
Red
One or more of the following conditions has
occurred:
• Temperature is out of range.
• The fan controller has failed.
• Two or more fans have failed.
Check the CLI to determine the exact condition of
the fans. Use the
show system
command.
If fans have failed, replace the fans. See
“
CPU
Off
Power off.
Ensure chassis has adequate power.
Amber
Blinking
. Device in bootup process.
None.
Solid
. Testing.
If the LED remains amber for several minutes,
contact Enterasys Networks for technical support.
Green
Blinking
.
Image starts running.
None.
Solid
. Functional.
None.
Red
Solid
. Processor in reset.
None.
Green
and
Amber
Blinking
.
Indicates that the SSA is in the
process of shutting down.
None. This state is activated when the RESET
button is pressed for less than 1 second to start an
orderly shutdown.
Amber
and off
Alternating (67% on, 33% off)
. Indicates a
shutdown is complete. The indication will
hold for 60 seconds then automatically
restart.
While in this state, you have 60 seconds before the
SSA will reboot.
PWR
Off
Device not receiving power from power
supply.
Ensure the power cords are plugged in and there is
power at the source.
Contact Enterasys Networks for technical support.
Green
Functional
. Power supply operating
normally.
None.
Amber
Indicates loss of power supply redundancy.
Ensure the power cords are plugged in and power
is available at the source.
Contact Enterasys Networks for technical support.
Blue
Solid.
Indicates, in PoE mode, that two
625W power supplies are installed.
None.
Blinking.
Indicates, in PoE mode, that one
625W power supply is installed.
None.
White
Solid.
Indicates, in PoE mode, that two
1000W power supplies are installed.
None.
Blinking.
Indicates, in PoE mode, that one
1000W power supply is installed.
None.
Blue/
White
Indicates, in PoE mode, that 625W and
1000W power supplies are installed.
None.
Table 3-3 System LEDs (continued)
LED
Color
State
Recommended Action
Summary of Contents for SSA-G1018-0652
Page 2: ......
Page 12: ...x ...
Page 16: ...xiv ...
Page 20: ...Getting Help xviii About This Guide ...
Page 46: ...Completing the Installation Pin Out Descriptions 2 22 Installation ...
Page 64: ...Using the OFFLINE RESET Button 3 18 Troubleshooting ...
Page 68: ...Regulatory Compliance A 4 Specifications ...
Page 76: ...Management of PoE Power to PDs C 4 About PoE Power over Ethernet ...