Backplane Connections and Installation Rules
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide
3-5
Example 4 (
Figure 3-2
,
D)
Shows
chassis
slots
1
through
5
populated
with
a
mix
of
6x1xx,
6x2xx,
and
6x3xx
modules
and
only
third
generation
modules
in
slots
6
and
7.
In
this
module
arrangement,
the
6x3xx
module
provides
a
proxy
bridge,
which
enables
the
6x1xx
and
6x2xx
modules
to
communicate
with
6x3xx
modules
in
slot
6
or
7.
If
more
than
one
6x3xx
module
is
installed
in
slots
1
to
5,
the
module
in
the
lowest
numbered
slot
performs
the
proxy
function
for
slots
6
and
7.
Therefore,
if
a
6x3xx
module
is
already
performing
the
proxy
function,
and
another
6x3xx
module
is
inserted
into
a
lower
numbered
slot,
connectivity
will
be
temporarily
interrupted,
as
the
new
board
takes
over
the
proxy
function.
When
a
6x3xx
module
in
a
lower
numbered
slot
is
removed,
and
there
is
a
6x3xx
module
in
a
higher
numbered
slot,
communication
is
not
interrupted.
For
Local
Management,
plugging
the
Local
Management
connection
into
the
6x3xx
modules
will
allow
management
connections
to
all
6x1xx,
6x2xx,
and
6x3xx
modules.
If
the
Local
Management
connection
is
to
a
6x1xx
or
6x2xx
board,
only
the
modules
in
the
first
five
slots
will
be
recognized
by
the
management
client.
Rule:
There
must
be
at
least
one
6x3xx
module
in
slots
1
through
5
to
enable
communications
between
the
6x1xx,
6x2xx,
and
6x3xx
modules.
Example 5 (
Figure 3-2
,
E)
Shows
chassis
slots
1
and
5
populated
with
6x1xx,
6x2xx
modules,
respectively;
slots
2
through
4
with
DFE
‐
Platinum
modules
without
a
bridging
module;
and
slots
6
and
7
with
6x3xx
modules.
In
this
module
arrangement,
the
6x1xx
and
6x2xx
modules
in
slots
1
and
5
can
only
communicate
with
each
other,
because
there
is
no
6x3xx
module
in
one
of
the
first
five
slots
to
serve
as
the
proxy
bridge
to
communicate
with
the
6x3xx
modules
in
slots
6
and
7.
The
7x4xxx
DFE
‐
Platinum
modules
in
slots
2,
3,
and
4
will
operate
under
one
IP
address.
Since
there
is
no
bridging
module
(7H4382
‐
25,
7H4382
‐
49,
7H4383
‐
49,
or
7H4385
‐
49),
the
DFE
‐
Platinum
modules
will
not
communicate
with
any
other
modules
in
the
chassis.
Rule:
In
this
example,
there
must
be
at
least
one
6x3xx
series
module,
and
a
bridging
module
(7H4382
‐
25,
7H4382
‐
49,
7H4383
‐
49,
or
7H4385
‐
49)
in
slots
1
through
5
to
enable
communications
between
all
generations
of
modules
in
the
chassis.
Example 6 (
Figure 3-2
,
F)
The
module
arrangement
in
this
example
is
similar
to
the
one
shown
in
Figure 3
‐
2
,
E
and
described
in
Example
5.
The
only
difference
is
that
a
bridging
module
is
installed
in
slot
2,
enabling
all
modules
to
communicate
with
each
other.
Rule:
In
this
example,
the
7H4382
‐
25
serves
as
both
the
FTM1
‐
to
‐
FTM2
bridge
and
the
five
‐
to
‐
seven
slot
proxy
bridge.
The
6x3xx
does
not
serve
as
a
proxy
bridge
in
this
configuration
because
the
7H4382
‐
25
is
in
a
slot
with
a
lower
number.
You
can
use
the
7H4382
‐
25,
7H4382
‐
49,
7H4383
‐
49,
or
7H4385
‐
49
as
a
bridging
module
depending
on
the
need.
Summary of Contents for Matrix 7G4282-41
Page 2: ......
Page 12: ...x...
Page 16: ...xiv...
Page 26: ...LANVIEW Diagnostic LEDs 1 6 Introduction...
Page 64: ...Regulatory Compliance A 4 Specifications...
Page 65: ...Regulatory Compliance Enterasys Matrix DFE Platinum Series Hardware Installation Guide A 5...