Backplane Connections and Installation Rules
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide
3-3
BACKPLANE CONNECTIONS AND INSTALLATION RULES
The
following
sections
describe
the
FTM1
and
FTM2
backplane
connections,
and
the
hardware
configuration
rules
when
installing
first
(6x1xx),
second
(6x2xx),
and
third
(6x3xx)
generation
modules,
and
DFE
‐
Platinum
modules
(7xxxxx)
into
the
same
Matrix E7
chassis.
FTM1 and FTM2 Connectivity
The
Matrix E7
(6C107)
chassis
has
backplanes
referred
to
as
FTM1
and
FTM2.
The
7xxxxx
DFE
‐
Platinum
modules
use
FTM2
for
high
speed
communication
to
each
other
and
operate
as
one
switching
unit
with
a
single
IP
address.
The
traffic
through
these
modules
does
not
connect
to
FTM1
except
through
an
FTM
bridging
module
such
as
the
DFE
‐
Platinum
7H4382
‐
25,
7H4382
‐
49,
7H4383
‐
49,
or
7H4385
‐
49.
Installation
Guides
for
these
bridging
modules
are
located
on
the
Enterasys
Networks
World
Wide
Web
site:
http://www.enterasys.com/support/manuals
.
The
FTM
bridging
modules
have
connections
to
both
FTM1
and
FTM2
backplanes,
which
enables
them
to
switch
frames
between
the
two
backplanes
and
all
modules
in
the
6C107
chassis.
However,
the
older
first
(6x1xx),
second
(6x2xx),
and
third
(6x3xx)
generation
modules
are
still
managed
using
their
own
Local
Management
and
are
not
subject
to
management
by
the
DFE
‐
Platinum
module
management
entity.
The
Matrix
N1
(7C111),
Matrix
N3
(7C103),
Matrix N5
(7C105
‐
P),
and
Matrix
N7
(7C107)
chassis
have
only
FTM2
connections
and
support
only
DFE
modules.
Module Placement and Rules
The
DFE
modules
can
be
installed
in
a
Matrix E7
(refer
to
“Matrix E7
Chassis,
Module
Placement,”
below,
for
placement
rules),
Matrix N1,
Matrix N3,
Matrix N5,
or
Matrix N7
chassis.
The
Matrix N1,
Matrix N3,
Matrix N5,
and
Matrix N7
chassis
support
only
DFE
modules
and
there
are
no
particular
rules
for
installing
modules.
Matrix E7 Chassis, Module Placement
Depending
on
the
modules
being
installed
in
the
Matrix
E7
chassis
and
to
help
ensure
proper
operation,
consider
the
following
examples
and
rules
for
module
placement
in
the
chassis.
Figure 3
‐
2
shows
five
examples
of
chassis
module
placement.
These
examples
are
described
below
along
with
the
applicable
module
placement
rule.
Summary of Contents for Matrix 7G4282-41
Page 2: ......
Page 12: ...x...
Page 16: ...xiv...
Page 26: ...LANVIEW Diagnostic LEDs 1 6 Introduction...
Page 64: ...Regulatory Compliance A 4 Specifications...
Page 65: ...Regulatory Compliance Enterasys Matrix DFE Platinum Series Hardware Installation Guide A 5...