Installing and Connecting a Redundant Power System
Enterasys A4 Fast Ethernet Switch Hardware Installation Guide
2-15
Figure 2-8
Fastening the STK-RPS-150CH8 to the Rack
Connecting the RPS Cable and AC
Power Cord
The redundant power supply is connected to the A4 switch using a 1 meter RPS cable.
To connect a redundant power supply, proceed as follows:
1.
Using a Phillips screwdriver, remove the cover from the redundant power supply connector
on the A4 switch.
2.
Connect one end of the RPS cable to the redundant power supply connector on the A4 switch.
Then connect the other end of the cable to the redundant power supply connector at the rear
of the RPS as shown in
3.
Connect the AC power cord to the AC input power connector on the RPS shown in
, then plug the AC power cord into the main AC power outlet.
The green Power LED on the front of the RPS will illuminate to indicate a successful
connection. If the LED remains off, proceed as follows:
a.
Check the AC power cord connection at the AC power source and make sure the power
source is within specification.
b. Check the AC power connection to the RPS.
c.
Swap the AC power cord with a known good one.
d. If the green LED continues to remain off, contact Enterasys Networks. Refer to “
” on page xvii for instructions. Otherwise, proceed to step 4.
1
STK-RPS-150CH8 chassis
2
Rails of 19-inch rack
3
Mounting screws
Summary of Contents for A4H124-24