Using LANVIEW
Troubleshooting
4-5
TX
(Transmit)
Off
Port enabled, and no
activity.
Should flash green every
two seconds indicating
BPDUs being sent if STA is
enabled and there is a valid
link.
1. Ensure that the STA is enabled
and that there is a valid link.
2. Contact Enterasys Networks for
assistance.
Green
Flashing
. Indicates activity.
Rate indicates data rate.
None.
Amber
Blinking
. Port in standby.
Port may be disabled due to
Spanning Tree.
1. Ensure that the port is not
disabled.
2. Contact Enterasys Networks for
assistance.
Red
Flashing
. Indicates collision
rate.
None, unless there is a large
amount of activity. In this case,
check for network configuration
problems or a defective device.
Solid
. Diagnostic failure.
Contact Enterasys Networks for
assistance.
The following port DPX and SPD LED indications are only valid when the LED MODE switch
is in the DPX-SPD position.
FDX
(Full
Duplex
Status)
Amber
Port is operating in standard
mode (10 Mbps or
100 Mbps).
None.
Green
Port is operating in full
duplex mode (20 Mbps or
200 Mbps).
None.
SPD (Speed
Status)
Amber
There is a link and the port
is operating at 10 Mbps.
None.
Green
There is a link and the port
is operating at 100 Mbps.
None.
Table 4-1
LANVIEW LEDs (Continued)
LED
Color
State
Recommended Action