NT PRESSURE TRANSDUCER MODELS 4100, 4210
12
User Guide | Entegris, Inc.
Ordering Information
Refer to the following for the desired configuration.
Model 4100 Single-port Pressure Transducer:
part number
4100 - - - - - -
Pressure range
030G = 207 kPa (30 psig)
060G = 414 kPa (60 psig)
100G = 690 kPa (100 psig)
150G = 1034 kPa (150 psig)
(Flaretek and Pillar
port connections
only)
Inlet/outlet port connection
F02 =
1
⁄
4
" Flaretek tube fitting
F03 =
3
⁄
8
" Flaretek tube fitting
F04 =
1
⁄
2
" Flaretek tube fitting
W02 =
1
⁄
4
" Super 300 Type Pillar tube fitting
W03 =
3
⁄
8
" Super 300 Type Pillar tube fitting
W04 =
1
⁄
2
" Super 300 Type Pillar tube fitting
N02 =
1
⁄
4
" FNPT
N04 =
1
⁄
2
" FNPT
M02 =
1
⁄
4
" MNPT
Electrical connector types
B06 = FEP-jacketed 6' pigtail electrical cable
B12 = FEP-jacketed 12' pigtail electrical cable
B30 = FEP-jacketed 30' pigtail electrical cable
D00 = Polypropylene connector (cable not included)
D06 = Polypropylene connector and 6' PVC cable
D12 = Polypropylene connector and 12' PVC cable
D30 = Polypropylene connector and 30' PVC cable
Primary/secondary seal
U3 = Kalrez 6375 UP / Viton
S3 = Kalrez 6375 UP / Kalrez 6375 UP
Sensor interface
P1 = CTFE sensor interface (default)
P2 = PFA sensor interface
Electrical outputs
A = 4–20 mA (12–30 VDC input)
B = 0–10 VDC (12–30 VDC input)
C = 0–5 VDC (12–30 VDC input)
Example:
4100-100G-F02-D06-A-P1-U3
• 4100 — Model
• 100G — Pressure range
• F02 — Inlet/outlet port connection
• D06 — Electrical connector type
• A — Electrical outputs
• P1 — Sensor interface
• U3 — Primary/secondary seal