393870-2 Rev 0: 11.07.2018 BBV
We reserve the right to change technical data without notice.
http://www.ensy.no
Page 22
TECHNICAL DATA
Reheating unit + fans
- phase/voltage
(50Hz/VAC)
~
1 / 230
- power consumption
(W)
1200
Recommended fuses
(A)
10
Control system
Integrated
Filter Class
Superpleat
F7
Thermal/sound insulation
(mm)
40
Weight, including brackets
(kg)
49,5
SPECIFICATIONS
•
Rotary heat exchanger with heat recovery up to 85 % efficiency.
•
Electric heating coil.
•
High efficiency and low noise EC fans. Adjustable 30 to 100 % speed.
•
Adjustable supply air temperature between 15 and 21°C.
•
Acoustic and thermal-insulated housing.
•
Control system with "Touch Panel" for the control of the unit supplied as standard and to be
connected outside the unit on “STYREPANEL 1” See page 19 or 20.
•
The unit is designed for optional connection of a cooker hood on the side of the unit.
In the end of unit there is:
(Look at page 19 and 20)
•
Junction point of contact for connection for an extra control panel. (STYREPANEL 2)
•
Junction point of contact for cooker hood. (KV)
•
Junction point of contact for Co² sensor. (CO ²)
•
Junction point of contact for pulse switch. (D1)
•
Junction point of contact for an external humidity sensor or motion detector. (D2)
•
Junction point of contact for connection for home / away function. (D3)
EXTRA
:
Extra control panel, desire more control points. Including 10 meters signal cable (Art. no: 0100051-2)
Wireless pulse switch. (Art. no: 0100052-2)
Suspension bracket for wall. (Art: 01008045-2) Look at page 17.