9. Technical Data

Product code

EVH020.02H

EVH050.02H

Charging connector

Type2 plug

Charging connectors

1

Charging current max.

16A 1-phase

3 x 16A 3-phase

Charging output

3.6 kW

11 kW

Nominal voltage

230V 1-phase

230V/400V 3-phase

Nominal current

1 x 16 A

3 x 16 A

Nominal frequency

AC 50/60 Hz

Supply connectors

3 (N, L, PE)

5 (L1, L2 L3,N, GND)

Supply connector type

Screw terminal Cu 2,5 - 6 mm²

Number of cable throughs

1

Installation

Directly to wall

Dimensions 

432 x 220 x 168 mm

Weight 

9 kg

Lenght of charging cable

4 m

Enclosure class

IP44

Shock protection rate

IK10

Operating temperature

-30 … +50 °C

Operating humidity

95% non condensating

Standby power consumption

<1W typical

Functional features

Status indicator LED’s

Summary of Contents for eFiller

Page 1: ...ENG Installation instructions Operation instructions RAK130_ENG 3 12 2018 Ensto 2018 eFiller...

Page 2: ...Current Limitation 7 3 5 Top Cover Installation 8 3 6 Plug Holder Installation 8 4 User Instructions 9 4 1 Start Charging 9 4 2 Stop Charging 9 4 3 User Interfaces 9 5 Troubleshooting 9 5 1 The vehic...

Page 3: ...al lation and service Follow the guidelines in the instruction manual when installing and using the charging point The installation must be done according to the local safety regulations restrictions...

Page 4: ...re the wall for installation and select the screw type depending on the wall type Recommended screw diameter is 6mm 8mm The mounting screw spacing is 120mm x 185mm Exercise extreme caution when drilli...

Page 5: ...he supply cable at the length of max 250mm Cut the leads in different lengths so that the PE cable is the longest and strip them at the length of 23mm Connect the supply cable leads to the supply conn...

Page 6: ...VI020 IN OUT L1 N L1 N PG CP L1 N PEPE CP N L1 PE PP X1 16A L2 L3 1 2 3 4 EVH020 02H SUPPLY 1 x 16A 230V max 6mm Cu 30mA RCD B and 16A MCB PG ProximityGround CP ControlPilot DIP1 ON DIP2 OFF DIP3 ON D...

Page 7: ...1 DIP2 DIP3 DIP4 DIP5 DIP6 Maximum charging current OFF OFF OFF OFF OFF OFF 6A ON OFF OFF OFF OFF OFF 8A OFF ON OFF OFF OFF OFF 10A ON ON OFF OFF OFF OFF 12A OFF OFF ON OFF OFF OFF 14A ON OFF ON OFF O...

Page 8: ...ing 3 6 Plug Holder Installation Install the plug holder to a wall so that the plug is handy to pick up and the placement is practi cal compared to location of the parked vehicle When selecting the in...

Page 9: ...e charging cable is connected and the vehicle has ended charging for example the battery is full Green blinking Malfunction Red stable No supply power for charging point No light 5 Troubleshooting 5 1...

Page 10: ...om inside of the charging point the configuration of the current limitation DIP switches If the charging current limitation is set to a lower charging current than as sumed the charging time is longer...

Page 11: ...rom the date of pur chase but no longer than 4 years from the date of manufacture if there is no other agreement The warranty is not applicable if the maintenance is not performed according to the ins...

Page 12: ...11 kW Nominal voltage 230V 1 phase 230V 400V 3 phase Nominal current 1 x 16 A 3 x 16 A Nominal frequency AC 50 60 Hz Supply connectors 3 N L PE 5 L1 L2 L3 N GND Supply connector type Screw terminal Cu...

Reviews: