background image

10

RAK130_ENG / © Ensto 2018

5.2 The indicator light is red

Potential errors and corrective actions:
• 

Unsupported configuration on the eFiller charging current limitation. Check the position 

on the DIP switches inside the charging point according to the table on page 7. 

Notice that opening the cover can only be done by electrically skilled person.

• 

Missing protective earth (PE). Check the PE availability from the supply line and condition 

of the charging cable.

• 

Error in the vehicle communication. Disconnect the vehicle, reset the charging point by 

turning supply voltage off and on. Retry charging. 

• 

Software error. Disconnect the vehicle, reset the charging point by turning supply voltage 

off and on. Retry charging.

• 

The vehicle requires ventilation. In case the vehicle requires ventilation during charging, 

eFiller does not allow charging.

5.3 The vehicle is charging slower than expected

• 

Ensure from the vehicle that the vehicle has no timer charging activated.  If the timer 

charging is activated, the charging time may be different than expected.

• 

Ensure from inside of the charging point the configuration of the current limitation DIP 

switches. If the charging current limitation is set to a lower charging current than as-

sumed, the charging time is longer. 

Notice that opening the cover can only be done by electrically skilled person

.

• 

Ensure that there is no charging current limitation features in use at the vehicle.

If you need to contact Ensto related to faulty operation of eFiller, please prepare to tell the 

order number (V.......). You will find the order number on the nameplate on the enclosure bot

-

tom.

6. Maintenance Instructions

With well-done maintenance you can ensure a long lifetime of the charging point and keep the 

warranty valid. 

Please proceed the following maintenance once in a month:
• 

Test the residual current device (RCD-B) at the supply line. Usually RCD’s have a test but

-

ton for this purpose. There might be local requirements on the RCD manual test interval, 

but Ensto recommends testing once a month. In case of failed test the RCD must be 

changed.

• 

Check the plug holder and the charging plug from possible dirt.  Remove possible dirt.

• 

Check the condition of the charging plug and the charging cable for wear out or mechani-

cal damage. If damaged, please replace necessary parts with new ones.

Summary of Contents for eFiller

Page 1: ...ENG Installation instructions Operation instructions RAK130_ENG 3 12 2018 Ensto 2018 eFiller...

Page 2: ...Current Limitation 7 3 5 Top Cover Installation 8 3 6 Plug Holder Installation 8 4 User Instructions 9 4 1 Start Charging 9 4 2 Stop Charging 9 4 3 User Interfaces 9 5 Troubleshooting 9 5 1 The vehic...

Page 3: ...al lation and service Follow the guidelines in the instruction manual when installing and using the charging point The installation must be done according to the local safety regulations restrictions...

Page 4: ...re the wall for installation and select the screw type depending on the wall type Recommended screw diameter is 6mm 8mm The mounting screw spacing is 120mm x 185mm Exercise extreme caution when drilli...

Page 5: ...he supply cable at the length of max 250mm Cut the leads in different lengths so that the PE cable is the longest and strip them at the length of 23mm Connect the supply cable leads to the supply conn...

Page 6: ...VI020 IN OUT L1 N L1 N PG CP L1 N PEPE CP N L1 PE PP X1 16A L2 L3 1 2 3 4 EVH020 02H SUPPLY 1 x 16A 230V max 6mm Cu 30mA RCD B and 16A MCB PG ProximityGround CP ControlPilot DIP1 ON DIP2 OFF DIP3 ON D...

Page 7: ...1 DIP2 DIP3 DIP4 DIP5 DIP6 Maximum charging current OFF OFF OFF OFF OFF OFF 6A ON OFF OFF OFF OFF OFF 8A OFF ON OFF OFF OFF OFF 10A ON ON OFF OFF OFF OFF 12A OFF OFF ON OFF OFF OFF 14A ON OFF ON OFF O...

Page 8: ...ing 3 6 Plug Holder Installation Install the plug holder to a wall so that the plug is handy to pick up and the placement is practi cal compared to location of the parked vehicle When selecting the in...

Page 9: ...e charging cable is connected and the vehicle has ended charging for example the battery is full Green blinking Malfunction Red stable No supply power for charging point No light 5 Troubleshooting 5 1...

Page 10: ...om inside of the charging point the configuration of the current limitation DIP switches If the charging current limitation is set to a lower charging current than as sumed the charging time is longer...

Page 11: ...rom the date of pur chase but no longer than 4 years from the date of manufacture if there is no other agreement The warranty is not applicable if the maintenance is not performed according to the ins...

Page 12: ...11 kW Nominal voltage 230V 1 phase 230V 400V 3 phase Nominal current 1 x 16 A 3 x 16 A Nominal frequency AC 50 60 Hz Supply connectors 3 N L PE 5 L1 L2 L3 N GND Supply connector type Screw terminal Cu...

Reviews: