9.
Technical Data
Supply voltage
230 V -15%, +10%, 50 Hz
Switch
2-pole
Rated current
10 A
Maximum load
2300 W
Nominal residual operating current
30 mA
RCD type
A
Operating temperature range
-20 ... +30 °C
Thermostat adjustment range
+5 ... +50 °C
Floor sensor
NTC, 47 kΩ/25°C, cable 4 m (extendable to 10 m)
Floor sensor resistance values
Table 1, on page 2 (sensor not connected)
Enclosure class
IP31
Pollution degree rating
2
Rated impulse voltage
4 kV
Power in standby
< 0,5 W
Radio frequency range
2,4 ... 2,483 GHz
Radio max. power
+3 dBm