7
RAK93 / © Ensto 2018
Charging Current Limitation
Configure the maximum allowed charging current with DIP switches at the charging controller. The
maximum current can be defined according to the following table.
NOTE! The configuration must be done by a qualified person e.g. an electrician.
To get to the control unit the front cover must be removed by loosing the four torx screws.
DIP1
DIP2
DIP3
DIP4
DIP5
DIP6
Maximum charging current
OFF
OFF
OFF
OFF
OFF
OFF
6A
ON
OFF
OFF
OFF
OFF
OFF
8A (EVH020.01R / EVH020.02R default)
OFF
ON
OFF
OFF
OFF
OFF
10A
ON
ON
OFF
OFF
OFF
OFF
12A
OFF
OFF
ON
OFF
OFF
OFF
14A
ON
OFF
ON
OFF
OFF
OFF
16A (EVH020.01 / EVH020.02 and
EVH020.01R16 / EVH020.02R16 default),
3 x 16A EVH050.02 / EVH050.02R16 default
EVI020
IN
OUT
L1
L1
N
N
ON
OFF
PE
CP
1 2 3 4 5 6
K1
1,5
1,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
Contactor
L1
L1
L1
L2
L2
L3
L3
A1
A2
L2 L3
L1 L2 L3
PE PE PE PE
N N N N
X1 16A
CP
PP
PE
L1
L2
L3
N
EVH050.02
SUPPLY
3 x 16A 230V
30mA RCD and 16A MCB
DIP1
ON
DIP2
OFF
DIP3
ON
DIP4
OFF
DIP5
OFF
DIP6
OFF