Learning in Remotes and Wireless devices: 

 

 

ZONE 1

 

1.

 

Press key P1 on the control unit once to program Relay 1 – Zone 1; the LED will remain on.  

2.

 

Press and hold a key to be learnt on the remote unit until the LED on the main control unit starts to flash; re-

lease the key.  

 

Z ONE2

 

1.

 

Press key P1 on the control unit twice to program Relay 2 - Zone 2; the LED will remain on.  

2.

 

Press and hold a key to be learnt on the remote unit until the LED on the main control unit starts to flash; re-

lease the key.  

 

Setting the Relay On Time: 

Only if TIMED MODE is used up to 4 minutes on time.

 

 

ZONE1

 

 

1.

 

Press key P2 on the main control unit 

once

 to set the Relay On Time for Zone 1, the LED will come on.

 

 

2.

 

Wait a length of time equal to the desired Relay On Time to be set for Zone 1, after which press key P2 again.

 

 

3.

 

The LED will flash three times to confirm.

  

 

ZONE2

 

1.

 

Press key P2 on the main control unit 

twice

 to set the Relay On Time for Zone 2, the LED will come on.

 

 

2.

 

Wait a length of time equal to the desired Relay On Time to be set for Zone 2, after which press key P2 again.

 

 

3.

 

The LED will flash three times to confirm.

  

 

DELETING Remotes or Wireless devices:

 

 

Deleting an individual remote or wireless device:

 

1.

 

Press and hold key P1 on the main control unit for 5 seconds (release the key); the LED will remain on. 

 

2.

 

Press the key on the Remote or trigger the wireless device to be cancelled until the LED begins to flash.

 

 

Deleting all remotes and wireless devices:

 

1.

 

Press and hold key P1 on the main control unit for approx. 10 seconds, the LED will come on, then release 

the key. 

 

2.

 

The LED will emit 3 flashes to confirm the deletion of all the codes.

 

 

Universal Wireless Transmitter: 

 

 

 

 

The universal wireless transmitter can be used to trigger the ENSA-RS1 Remote Switch from any dry contact 
switching device such as a door or gate open reed, proximity or limit switch.   

 

The reed bypass jumper must be connected for the external switch terminals to function.  

 

Wire to dry contacts only no voltage is to be applied to the terminals.  

 

Range, up to 200 meters line of sight depending on conditions. 

Summary of Contents for ENSA-RS1

Page 1: ...to 4 minutes Specifications AC Input 220 240VAC AC Output 220 240VAC Power Frequency 50Hz Max Load 5 Amp s Total Operating Feq 433MHz Range 100 Meters line of site Dimensions 115 x 100 x 60mm IP Rating IP55 There are many ways how you may use the ENSA RS1 2 Channel Receiver below are some examples 1 Using the ENSA RS1 as a 2 channel remote switch This Remote Switch that can used to remotely turn o...

Page 2: ...and the device that is connected to the zone Installation and Configuration Instructions WARNING 1 Before opening the cover of the ENSA RS1 ensure the power supply to the device is isolated 2 Read the installation instruction before attempting to wire up the device 3 This product is for installation only by a qualified Electrician The remotes included in the pack are already programmed and ready t...

Page 3: ...ED will come on 2 Wait a length of time equal to the desired Relay On Time to be set for Zone 2 after which press key P2 again 3 The LED will flash three times to confirm DELETING Remotes or Wireless devices Deleting an individual remote or wireless device 1 Press and hold key P1 on the main control unit for 5 seconds release the key the LED will remain on 2 Press the key on the Remote or trigger ...

Page 4: ...omplete PIR showing mounting box Dual Heads and Universal Transmitter Fig 3 Mounting Box showing Tamper PIN After selecting a suitable site for the PIR mark out and drill mounting holes for mounting box Insert the Tamper Pin from the rear as show above then mount the Box Fit the PIR and the weather cover to the mounting box with the 3 screws provided Take care that wires to the universal transmitt...

Reviews: