Introduction 

We are pleased that you have purchased a Manumed ST treatment couch. 
This examination and treatment couch is specially designed for the demands of the physical and 
manual therapist. The anatomically segmented top part combined with the wide array of section 
positions enable you to position your patient virtually however you wish. The Manumed ST is 
available with a hydraulic or an electric height adjustment. 
During development and production of this Manumed ST a great deal of care was put into the 
reliability, safety, ease of use and durability. It is important to read the following instructions 
carefully before using your Manumed ST treatment couch properly and safely. 

 

This manual applies to:  

 

Manumed ST 2-section, head section 

 

Manumed ST 2-section, back section  

 

Manumed ST 3-section  

 

Manumed ST accessories 

 
 
 

2

 

Symbols 

Symbol used 

Description 

 

 

 

Follow the instructions in the Instructions for Use. 
It is important that you read, understand and observe the precautionary and 
operating instructions 

 

 

 

Warning or Caution: 

Indicates a hazardous situation which, if not avoided, could result in: 

a.

 

Death or serious injury to the patient (or) 

b.

 

Minor to moderate injury to the patient (or) 

c.

 

Damage to the equipment 

 

 

 

Temperature Range. 
Indicates acceptable temperature range 

 

 

 

Humidity Limits. 
Indicates acceptable relative humidity 

 

 

 

Atmospheric Pressure. 
Indicates the range of atmospheric pressure to which the medical device can 
be safely exposed. 

 

 

 

Waste electrical items that can be recycled. 
Indicates the electrical and electronic components of the device can be 
recycled and has to be disposed separately. 

 

 

 

Manufacturer name, address and date of manufacture. 

 

 

  

 

 

Summary of Contents for Manumed ST

Page 1: ...Manumed ST EN109 1560750 44 APRIL 4 2022 Instructions for use...

Page 2: ...3 2 Symbols 3 3 Package contents 4 4 Installation 5 5 Intended use and intended user 5 6 Precautionary instructions 6 7 Operation 7 8 Safety instructions 9 9 Cleaning maintenance and troubleshooting...

Page 3: ...o Manumed ST 2 section head section Manumed ST 2 section back section Manumed ST 3 section Manumed ST accessories 2 Symbols Symbol used Description Follow the instructions in the Instructions for Use...

Page 4: ...d water by mechanical casings and electrical enclosures Double Insulation Type B applied part complying with the specified requirements to provide protection against electric shock particularly regard...

Page 5: ...d ST should be placed on a flat surface Turn the adjustable foot until it touches the ground and the couch is standing stable For correct assembly and safe use of possible optional accessories one mus...

Page 6: ...nt to be used by competent personnel in physiotherapy rehabilitation or adjacent areas Avoid any use of the equipment by unauthorized personnel When used by children supervision by a knowledgeable par...

Page 7: ...upports the full weight of the patient Each section of this Manumed ST is supported by gas springs As well as easing operation they offer full support of the sections However these gas springs are not...

Page 8: ...ed underneath the framework with your foot the required height of the couch can be set At the head section of the couch the height can be adjusted by turning the handle to the left or to the right Nev...

Page 9: ...eside the couch is set in flexion position combined with the lowest possible position Underneath the head section between the head section and floor Danger of tilting Do not sit on the head and leg se...

Page 10: ...clean water Disinfection Clean the couch as described above before proceeding to disinfect the couch Follow the disinfectant s instructions for use Never use a mixture of disinfectants or a disinfecta...

Page 11: ...service life This device will remain suitable for its intended use as long as it is subjected to yearly maintenance by a qualified service engineer as described in the service manual and the service...

Page 12: ...EN ISO 10993 5 DIN EN ISO 10993 10 Technical modifications reserved Safety and performance standards This equipment complies with all requirements of the Medical Device Regulation EU 2017 745 Medical...

Page 13: ...rs be liable for any indirect special incidental or consequential damages arising from the use of or inability to use the product including without limitation damages for loss of goodwill work and pro...

Page 14: ...EN109 1560750 44 Copyright Enraf Nonius B V Vareseweg 127 3047 AT Rotterdam The Netherlands Tel 31 0 10 20 30 600 info enraf nonius nl...

Reviews: