background image

 

 

 

 

 

 

 

   

EN109-1413761-43 IFU

 

 

 
 
 

CROSSWALKER 

Instructions for Use 

 

 

 

 
 
 
 
Part number: EN109-1413761-43 IFU 
January 5, 2021

 

 
 

 

 

Summary of Contents for 1413931

Page 1: ...EN109 1413761 43 IFU CROSSWALKER Instructions for Use Part number EN109 1413761 43 IFU January 5 2021 ...

Page 2: ...09 1413761 43 IFU TABLE OF CONTENTS 1 INTRODUCTION 3 2 SYMBOLS 4 3 PACKAGE CONTENTS 6 4 SETUP 7 5 USING THE DEVICE 8 6 OPERATION 12 7 MAINTENANCE 20 8 ORDERING INFORMATION 21 9 SPECIFICATIONS 22 10 PRODUCT LIABILITY 23 ...

Page 3: ...osswalker This ergometer is intended for stationary training and to help you treat patients in the field of physical medicine and rehabilitation We hope that this will be a valuable device in the execution of your profession and that it will improve the health and quality of life of many people ...

Page 4: ...EU 2017 745 Name and contact information of the manufacturer and production date Reference or model number Serial number used for identification of the device Indicates that the item is a medical device Indicates a carrier that contains Unique Device Identifier information Indicates Type B applied parts No electrical contact with Patient and may be earthed Indicates the range of atmospheric pressu...

Page 5: ...Page 5 of 24 EN109 1413761 43 IFU Emergency stop button Risk of crushing hands Risk of crushing feet Fuse properties Alternating current 2x T6 3 250V AH ...

Page 6: ...rosswalker art nr 1413931 you will find enclosed 1x 1413769 Instructions for Use PDF on CD 1x 1413765 Information Booklet 1x 3444298 Power cord Use of accessories and cables other than those specified or provided by the manufacturer of this equipment is NOT allowed ...

Page 7: ...of the frame After the mains cable has been connected switch on the device by using the switch located next to the mains cable connection The Crosswalker is now ready for use In case of damage contact your local distributor Do NOT use the device To avoid the risk of electric shock this equipment must only be connected to a mains supply with protective earth No unauthorized modification of this equ...

Page 8: ...ons the devices can and can not be used Following the ACSM recommendations for preparticipation health screening the professional user should screen every patient by a self reported medical history or health risk appraisal questionnaire The need and degree of follow up is determined by the answers to these self guided methods Patients diagnosed with the following disease should consult with their ...

Page 9: ...ors from the list below should be encouraged to consult with their physician prior to initiating a vigorous intensity physical activity program These risk factors include You are a man 45 yr You are a woman 55 yr You smoke or quit smoking within the previous 6 months Your blood pressure is 140 90 mm Hg You do not know your blood pressure You take blood pressure medication Your blood cholesterol le...

Page 10: ...enotic valvular heart disease Electrolyte abnormalities e g hypokalemia or hypomagnesemia Severe arterial hypertension i e systolic blood pressure SBP of 200 mm Hg and or a diastolic BP DBP of 110 mm Hg at rest Tachydysrhythmia or brady dysrhythmia Hypertrophic cardiomyopathy and other forms of outflow tract obstruction Neuromotor musculoskeletal or rheumatoid disorders that are exacerbated by exe...

Page 11: ...t and contact the supplier or Enraf Nonius B V for service Before starting any training or test please make sure the patient is screened thoroughly and you are sure there will be no adverse effects for the health of your patient Always provide the patient with clear information about the training or test State the purpose of the training or test what is going to happen and what is expected of the ...

Page 12: ...o adjust another parameter touch the screen to activate that parameter If no arc appears above this parameter it means it cannot be adjusted HOME MENU After switching on the device a welcome screen will be displayed while the device performs a self test At the end of the self test the unit enters the Home Menu and is ready for use Before starting any training or test please make sure the patient i...

Page 13: ... rate The arc above the displayed level indicates that the rotary knob can be used to adjust the level By default the elapsed time will be displayed When pressing the show more tab on the right side more parameters will appear The screen will show Elapsed time min sec Speed km h Cadence rpm Distance covered km Heart rate bpm when the chest belt is used Energy used kJ The training will start automa...

Page 14: ...to accurately set the power in Watts The power will be kept at the selected level independent of the cadence Please note The slower the cadence rpm the higher the force for each rotation will be Torque Choose training on torque when you want to control the amount of force on the walking mechanism The advantage of this training method is that when due to fatigue the cadence drops the amount of forc...

Page 15: ...rning the rotary knob Select the max heart rate to set this value in the same way HILL PROFILES This menu includes 12 set training programs Profiles 1 6 are displayed Use the rotary knob to go to page 2 profile 7 12 The power you need to set is the maximum power for this program Depending on the profile the power will vary between 50 and 100 of this value Apart from the profile and its maximum pow...

Page 16: ...ent data and the purpose of the training e g warming up endurance training etc The device will help you set the applicable target heart rate by means of several training zones Time Choose Time if the goal is to for instance train for 10 minutes Use the rotary knob to set the time Select the mode of training by touching the applicable button on the right and adjust to the desired value by using the...

Page 17: ... option if the goal is to cover a certain distance Again choose a training mode The intensity can be adjusted during training Energy Choose energy when your goal is to burn a specific amount of energy This might be relevant when weight control is important ...

Page 18: ...eart rate by means of several training zones When selecting heart rate as the training goal the training zones are displayed Before starting any training or test please make sure the patient is screened thoroughly and you are sure there will be no adverse effects for the health of your patient To define the right heart rate for the selected training zone we need to know the maximum heart rate Firs...

Page 19: ...pressing OK Before training starts the screen will display the target heart rate that was selected based on the training zone and patient s max heart rate Gaming This Crosswalker includes a gaming option We believe the gaming aspect will make it more fun for patients to work out and therefor easier to spend a certain amount of time on the Crosswalker RPM Airlines Just set the goal time and the dif...

Page 20: ...et to prevent injury CLEANING Before performing any cleaning switch off the device and disconnect the plug from the mains supply Clean the device with a damp cloth using a household cleaner Do not spray the cleaning agent directly on the glass panel Do not use cleaning agents that contain strong alkalis lye acid detergents with fluoride or detergents with ammonia This may cause damage to the devic...

Page 21: ... 3496837 Sigma Sport chest belt for heart rate monitoring 3496838 Elastic strap for Sigma Sport chest belt for heart rate monitoring The latest version in electronic or printed format of this Instructions for Use can be obtained free of charge from our website http www enraf nonius com or by contacting distributor or by calling the telephone number 31 0 10 2030600 the Instructions for Use will be ...

Page 22: ...possible with optional chest belt Exercise modes Levels Torque Power Heart rate Programs 12 pre programmed hill profiles Parameters Time Speed Cadence Distance Heart rate Energy ENVIRONMENTAL CONDITIONS Operating conditions Temperature 10 40 C Humidity 10 90 Air pressure 700 1060 hPa Storage and transport conditions Temperature 20 70 C Humidity 10 90 Air pressure 500 1060 hPa SAFETY AND PERFORMANC...

Page 23: ... and productivity computer failure or malfunction or any and all other commercial damages or losses even if advised of the possibility thereof and regardless of the legal or equitable theory contract tort or otherwise upon which the claim is based In any case Enraf Nonius entire liability under any provision of this agreement shall not exceed in the aggregate the sum of the fees paid for this prod...

Page 24: ...Page 24 of 24 EN109 1413761 43 IFU Copyright Enraf Nonius B V Vareseweg 127 3047 AT Rotterdam The Netherlands Tel 31 0 10 20 30 600 Fax 31 0 10 20 30 699 info enraf nonius nl www enraf nonius com ...

Reviews: