Enraf-Nonius B.V.
Curapuls 670 Service Manual
1403773
Introduction
June 1997
1-3
1.1.5
Product documentation
The documentation set for the Curapuls 670 also incudes an Instruction manual and
therapy books. The instruction manual is a recommended item for all service
engineers.
Ordering data:
-
1403.751
Instruction manual
-
1403.773
Service manual
-
1419.767
“Shortwave therapy"
-
1419.781
Service manual “Curamed and Curapuls accessories”
Therapy books:
-
1430.761
“Hoogfrequent Electrotherapie met de Curapuls 670" Dutch language
-
1430.762
“Pulsed short wave therapy with the Curapuls 670" English language
-
1430.763
“Pulsed short wave therapy with the Curapuls 670" German language
-
1430.764
“Pulsed short wave therapy with the Curapuls 670" French language
-
1430.765
“Pulsed short wave therapy with the Curapuls 670" Spanish language
1.1.6
Installation
For installation of the Curapuls 670 see the Operating Instruction manual.
Also:
-
It is not allowed to use this unit in so-called "wet rooms" (hydrotherapy rooms).
-
The mains supply connections must comply with the national requirements regarding
medical used rooms.
-
Before connection of this apparatus to the mains supply, check that the mains
voltage and frequency stated on the type plate of this apparatus correspond to that
of the mains supply. The 220-240V model is intended for nominal mains voltages of
220, 230 or 240 volt. The 115V model is intended for nominal mains voltages of 110
or 120 volt.
-
This apparatus must only be connected to a wall socket with protective earth
connection.
-
A potential equalisation cable may be connected to this unit if prescribed in the
national regulations.
1.1.7
Modifications
This publication could include technical inaccuracies or typographical errors. Changes
are periodically made to the information herein; these changes will be published as
Service Info's in appendix C of this Service Manual.
1.1.8
Product evaluation
In order to continuously improve the quality of our products, Enraf-Nonius requests her
service organizations to report any structural problem which may be discovered. When
the same problem regularly occurs or when safety problems occur, we would like you to
send us a product complaint report. The report must contain the name, the type of the
Summary of Contents for 1403773
Page 1: ...Curapuls 670 SERVICE MANUAL Part number 1403773 ...
Page 2: ......
Page 6: ...Enraf Nonius B V Curapuls 670 Service Manual 1403773 Index June 1997 4 ...
Page 16: ...Enraf Nonius B V Curapuls 670 Service Manual 1403773 Test equipment and tools June 1997 3 2 ...
Page 30: ...Enraf Nonius B V Curapuls 670 Service Manual 1403773 Maintenance June 1997 4 14 ...
Page 32: ...Enraf Nonius B V Curapuls 670 Service Manual 1403773 Storage and transport June 1997 5 2 ...
Page 48: ...Enraf Nonius B V Curapuls 670 Service Manual 1403773 Appendix B June 1997 B 12 ...
Page 56: ......
Page 58: ...No SI 670 02 Oct 1998 Page 2 of 2 Figure 1 Detail of the main PC Board ...
Page 59: ......