background image

 

39

I. BREAKER 
J. EXTERNAL BATTERY CONNECTOR 
K. BYPASS SWITCH 
L. SNMP SLOT 
M. RS232 + EPO 
N. TVSS 
O. USB 
P. REMOTE CONTROL PORT 

 

 

 

 

 

(3)

 

Connect the Battery cabinet to UPS:

 

 

(4)

 

FEATURE of REMOTE CONTROL FUNCTION:

 

a.

 

Remove the original right side panel and take apart the control panel unit. Then assemble 
the blank right side panel. 

Summary of Contents for EVO UPS 10000VA

Page 1: ...I U P S 6K VA 10K VA USER S MANUAL 2011 11 v 1 0 ...

Page 2: ... recommended to use one of the following preventive measures Place the receiving antenna in a separate location or orientation Ensure a greater distance is achieved between the receiver and the equipment Ensure that your equipment is connected to an outlet on a separate circuit than the receiver Contact a technician experienced with radio and TV or a dealer for further assistance Declaration of Co...

Page 3: ... loads 6000 10000 VA 13 5 4 Default settings at the factory 15 6 Computer and alarm connections 16 6 1 EPO port emergency power off 17 7 User s guide to operations 17 7 1 Starting and shutting down the UPS 18 7 2 Button operation 18 7 3 Control panel functions 19 7 4 Interpreting UPS messages 23 7 5 Trouble shooting 24 8 Maintenance 25 9 Technical Specifications 26 10 VGD RM 6KVA 3U 3U Mechanical ...

Page 4: ...AUTION Do not dispose of batteries in a fire the battery may explore CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles W...

Page 5: ...utlet where easily accessible Except replacing the batteries all servicing on this equipment must be carried out by qualified service personnel Before conducting any maintenance repair or shipment first ensure that everything is turned off completely and disconnected For additional safety instructions please use the Safety Manual as reference Special Symbols The following symbols used on the UPS w...

Page 6: ...is to protect these systems from poor quality utility power complete loss of power or other associated problems Electrical interference abounds in many forms causing problems in AC power from lightning power company accidents and radio transmissions to motors air conditioners and vending machines among others So protection of sensitive electrical equipment is vital to protect against power outages...

Page 7: ...btain greatest efficiency Irregularities can be detected in less than a second and on line mode reactivated immediately Switching back to online mode occurs when input voltage is outside 10 or nominal 15 selectable when input frequency is outside of 3Hz or when no input line is available Although high efficiency is standard the default operation is in on line mode Bypass can be F F F Fi i i il l l...

Page 8: ... operation a battery discharge test is performed and any problems reported on the LCD display Except during the first 24 hours after startup while the UPS is in charging mode please see chapter 7 2 diagnostic tests can be performed manually from the front panel at any time 2 2 System configuration The UPS device and the internal backup battery make up the system Depending on the site and load requ...

Page 9: ...the unit in position as marked on the packaging and never drop the unit Installation If flammable substances such as gases or fumes are present or if the room is airtight a safety hazard situation exists in which no electrical equipment should be operated The instructions in this manual explain how to install the UPS safely Not acknowledging such electrical hazards may be fatal so keep this manual...

Page 10: ...to 25 C Ensure that the equipment is fully protected from wet or damp areas and from moist air In order to maintain the vitality of the batteries ensure that the UPS is recharged every 6 months for at least 8 hours 5 Installation 5 1 Environment Ensure that all environmental concerns and requirements are met according to these technical specifications otherwise the safety of installation personnel...

Page 11: ...UPS or under the UPS Caution The UPS and the External Battery Pack are to be installed at the same location In case the UPS and the External Battery Pack are installed outside of visible distance then subject to the local inspection authority User will need to add a Safety disconnect adjacent to the UPS to provide safety isolation 5 2 Rear panel views 6000VA Tower Rear panel ...

Page 12: ...12 10000VA Tower Rear panel ...

Page 13: ...The high voltage and current contained within the UPS equipment can injure or kill personnel and damage equipment For electrical installation closely observe the nominal current rating of the source Installing External battery cabinets First disconnect the UPS from mains and loads before attempting an External Battery Cabinet installation Use the battery cable provided with the External Battery Ca...

Page 14: ...ral status of the mains supply is unreliable an additional two pole disconnect device is necessary in the building installation At the back of the unit you will find the Emergency Power Off EPO which when open will immediately shut down the logic circuit output of the UPS as in figure 2 to 4 Wiring the EPO signal is optional Caution Local safety requirements may require a separate external Emergen...

Page 15: ...ting 208 220 230 240 Vac 230V FOR HV series Input Bypass Voltage 10 10 15 15 20 10 15 Input Frequency 2 5 7 5 HE Mode Setting On Off Off Free Run Mode On Off On Bypass Enable Disable at free run mode Disable Enable Disable Alarm silence On Off Off Site wiring alarm Enable Disable Disable External Battery pack setting 0 1 2 0 You may change default settings but we recommend that this is done after ...

Page 16: ...and the AS 400 card allows voltage free relay contacts Your local dealer will have more information about these option cards Connecting the UPS to a Computer The communication device for the UPS and PC comes as a complete package with power management software Only the communication cable provided with UPS may be used to connect to your computer which is accomplished through the UPS RS232 port Als...

Page 17: ... can be bought separately 6 1 EPO port emergency power off A customer supplied switch located remotely can be used to open the EPO connection and allows UPS output receptacles to be switched off Since the EPO shuts down the equipment immediately orderly shutdown procedures are not followed and not by any power management software The UPS will have to be manually restarted in order to regain power ...

Page 18: ...nd turn off the loads Push the ON OFF button on the front panel for two seconds The alarm will sound and the UPS will shut down The LCD will display UPS OFF for a few seconds In emergency situations the EPO located on the back of the unit should be used 7 2 Button operation Please note the five operating buttons on the front panel 1 ON OFF button a Push ON OFF button at least 1 seconds to turn on ...

Page 19: ... button to enter enable or confirm the function that you want 5 ESCAPE button Use this button to return to main display Line mode or Battery Mode 7 3 Control panel functions Operation of the UPS is indicated on the monitor panel with five LED indicators and an LCD screen This display is also capable of alerting the user with audible alarms ON This green LED is lit when UPS has been turned on ON LI...

Page 20: ...escription O P VOLT xxx xV Shows Output AC voltage O P FREQ xx x Hz Shows Output Frequency I P VOL T xxx xV Shows Input AC voltage I P FREQ xx x Hz Shows Input Frequency BAT VOLT xx xV Shows Battery Voltage O P LOAD xx Shows Load of max load O P W xW Shows Output Watts O P VA xVA Shows Output VA O P CURR xA Shows Output Current BACKUP TIME xx min Shows Estimated Backup time in minutes BAT CHARG xx...

Page 21: ...ugh the options for the selected parameter 6 Press the ENTER button to select the option You may be prompted to save the selection if so press the ENTER button to either confirm or save your selection Other options are saved and started automatically See the table below for further details 7 If no buttons are pressed or user inactivity for ten seconds the UPS shall exit the configuration mode and ...

Page 22: ...y ON OFF OFF Do Battery Test Battery Test Detect battery is normal or not Silence Function Silence Set Enable or disable silence function ON OFF OFF Number of External battery Packs Bat Cabinet Set This setting is needed For UPS to predict Backup time 0 only internal batteries 1 one external cabinet 2 two external cabinets 0 Site wiring alarm Sit Fault Set You can enable or disable the site wiring...

Page 23: ...ndicators The UPS gives the following audible alarms If UPS is on battery and the ON BATTERY LED is on UPS will beep every 5 seconds If the battery capacity is low and the ON BATTERY LED is flashing the UPS will beep twice every 5 seconds If UPS is on bypass and the BYPASSED LED is on UPS will no beep If UPS has an internal fault and the ALARM LED is on the UPS will give a constant audible alarm d...

Page 24: ... 5 seconds The unit is operating on Battery Power Save your data and perform a controlled shutdown Charger Failure Constant beep Charger has failed Phone the local dealer Over Temperature Constant beep High ambient Temperature Make sure the unit s fans and vent holes are not blocked and make sure the ambient surrounding temperature is not above 40 degree C If these conditions did not solve the pro...

Page 25: ...f 6 to 12 months whether the back up time of the battery is adequate for its WARNING Batteries may cause electrical shock or burn from high short circuit currents Please observe the following precautions 1 Remove jewelry and metal objects such as watches and rings 2 Use tools that have insulated handles 3 Keep tools and other metal objects from contacting and away from the batteries ELECTRIC ENERG...

Page 26: ... line mode back up mode battery capacity load level Audible Alarm Battery back up Beep every 5 sec UPS Fault Continuous beeping sound and LCD display Communication RS 232 Serial Port and USB Battery Type Sealed maintenance free lead acid batteries DC Voltage V Battery Tower 240V 12V7AH x 20 240V 12V9AH x 20 Typical Recharge Time to 90 Full 4 hours Management Self test adjustable battery transfer p...

Page 27: ...ow fault red Visual Display LCD model Input output voltage input output frequency on line mode back up mode battery capacity load level Audible Alarm Battery back up Beep every 5 sec UPS Fault Continuous beeping sound and LCD display Communication RS 232 Serial Port and USB Battery Type Sealed maintenance free lead acid batteries DC Voltage V Battery Tower 240V 12V7AH x 20 240V 12V9AH x 20 Typical...

Page 28: ...20 for 30 seconds and 121 150 for 10 seconds Short Circuit Protection UPS output cut off immediately or input fuse circuit breaker protection System Display Warning Visual Display LED model UPS on green line mode green battery mode yellow bypass yellow fault red Visual Display LCD model Input output voltage input output frequency on line mode back up mode battery capacity load level Audible Alarm ...

Page 29: ...1 Protection and Filtering Surge Protection IEC 61000 4 5 level 3 Overload Protection 106 120 for 30 seconds and 121 150 for 10 seconds 106 120 for 30 seconds and 121 150 for 10 seconds Short Circuit Protection UPS output cut off immediately or input fuse circuit breaker protection System Display Warning Visual Display LED model UPS on green line mode green battery mode yellow bypass yellow fault ...

Page 30: ...re 20 50 C 4 122 F Altitude 2000 meters max Audible Noise 1 meter from surface 60 dBA 60 dBA Relative Humidity 0 95 humidity non condensing Conformance Safety CE EMC EMS EMI EN 62040 2 CISPR 22 EN 62040 2 EN 62040 2 CISPR 11 Equipment Protection Policy Warranty policy may vary depends on region Power Dissipation 1433 BTU h 2389 BTU h WARNING When power supplied by external batteries output toward ...

Page 31: ...38 10 RM 6KVA 3U 3U Mechanical A VGD 6K RACK MOUNT 3U 3U DESIGN 1 BASIC COMPONENT INCLUDING 3U UPS 3U BATT CABINET FRONT VIEW REAR VIEW 2 UPS REAR PANEL COMPONENTS H TERMINAL BLOCK ...

Page 32: ...MP SLOT M RS232 EPO N TVSS O USB P REMOTE CONTROL PORT 3 Connect the Battery cabinet to UPS 4 FEATURE of REMOTE CONTROL FUNCTION a Remove the original right side panel and take apart the control panel unit Then assemble the blank right side panel H J M N O I P L K ...

Page 33: ...40 b Connect the Control panel unit and Remote control port from rear side c Running the remote control function ...

Page 34: ...41 B 5 in 1 FUNCTION BRACKETS on RACK MOUNT 3U DESIGN 1 19 Rack installation Mount the 3U rack mount in a 19 inch EIA 310 C standard rack ...

Page 35: ... inch EIA 310 C standard rack 3 Tower installation a Move the mounting brackets from the front to the side and attach the brackets by screws Then let the UPS stand with the vertical direction as the below pictures shown b Rotate the control panel unit from horizontal to vertical direction 19 rack 23 rack width ...

Page 36: ...nting brackets from the front to the side and attach the brackets by screws Then mount the UPS to the wall as the below pictures shown 5 Installation with rear Bracket We can use bracket to support the rear side of UPS or battery cabinet ...

Page 37: ...44 ...

Page 38: ...ep sound and see SHUTDOWN on the screen The release ON OFF button later you will see UPS OFF text appears and disappears STEP 2 While display panel shows no text but only backlight turn off input breaker STEP 3 After turning off input breaker turn off battery breaker until all fans stop to complete the VGD shutdown procedures ...

Page 39: ...ct the option On You may be prompted to save the selection if so press the ENTER button to either confirm or save your selection Other options are saved and started automatically See the table below for further details 8 If no buttons are pressed or user inactivity for ten seconds the UPS shall exit the configuration mode and return to normal mode displaying Line mode 9 After switching to Manual B...

Page 40: ...r 6 You will see Manual Bypass is On 7 Press the FUNC button to scroll through the options for Manual Bypass till you see option Off 8 Press the ENTER button to select the option Off You may be prompted to save the selection if so press the ENTER button to either confirm or save your selection Other options are saved and started automatically See the table below for further details 9 If no buttons...

Reviews: