Q U I C K   I N S T A L L   G U I D E 

Installing the 

Enphase Q Aggregator

To install the Enphase Q Aggregator, read and follow all warnings and instructions in this Guide and in the 

Enphase IQ Series Microinverter Installation and 

Operation Manual

 at 

enphase.com/support

. If you do not fully understand any of the concepts, terminology, or hazards outlined in these instructions, refer 

installation to a qualified electrician or installer. These instructions are not meant to be a complete explanation of a renewable energy system. All installations 

must comply with national and local electrical codes. Professional installation is recommended.

IMPORTANT: 

Enphase IQ Series Microinverters require the Q Cable and are not compatible with previous Enphase cabling. An IQ Envoy is required to 

monitor performance of the IQ Microinverters. The Q Accessories work only with Enphase IQ Series Microinverters.

PREPARATION

A )  Check the box for the following items:

• 

Enphase Q Aggregator

• 

One bulkhead connector cap (Q-BA-CAP). You may need to order an 

extra cap if you connect only one branch circuit to the aggregator.

• 

Quick Install Guide

 (this document)

B )  Check that you have these 

required

 items:

• 

Enphase Q Aggregator(s) for multiple branch arrays

• 

Drill with an appropriately sized hole saw for conduit entry

• 

Wet/dry-rated conduit gland and conduit for home run entry

• 

Screwdrivers

• 

Wire stripping tool

• 

Torque wrench and sockets for mounting hardware

• 

75°C to 90°C copper conductors for connections between the Q 

Aggregator and main PV breaker

• 

Enphase disconnect tool

C )  Protect your system with lightning and/or surge suppression devices at 

the sub or main panel. 

D )  Protect the Q Aggregator with a maximum 60-amp over-current 

protection device (OCPD). 

E )  Size the AC wire gauge to account for voltage rise. Select the correct 

wire size based on OCPD size and on the distance from the beginning 

of the Enphase Q Cable to the breaker in the load center. Design for a 

voltage rise total of less than 2% for the sections from the Enphase 

Q Cable to the breaker in the load center. Refer to the Voltage Rise 

Technical Brief at 

enphase.com/support

 for more information. 

 

Best practice:

 Use a Q Aggregator and Enphase Q Field Wireable 

Connectors to center-feed each branch circuit to minimize voltage rise 

in a fully-populated branch.

F )  Plan to install the Q Aggregator in a location that will be under the 

modules when the array is complete.

AC connector

Enphase 

IQ 6 Micro or  

IQ 6+ Micro

DC connectors

Enphase Q  

Aggregator

AC connections

terminator

Enphase 

Q Cable

Cable clips or 

tie wraps

Features

• 

Lets you install systems up to 11.5 kW with only two line 

conductors and a ground coming from the roof

• 

Usable in any position up to 45 degrees from horizontal 

(NEMA 3R, includes drain holes)

• 

The aggregator bracket is ready to install on rail, can be flipped 

for roof or block mount installs, and allows you to fit conduit 

into either or both sides

How It Works

Use the Enphase Q Aggregator to bring together up to three 

branches of microinverters, center feed branch connections, 

or connect a remote part of the array using Enphase Q Field 

Wireable Connectors. 

Enphase 

disconnect 

tool

(Model Q-BA-3-1P-60) 

Summary of Contents for Q-BA-3-1P-60

Page 1: ...en the Q Aggregator and main PV breaker Enphase disconnect tool C Protect your system with lightning and or surge suppression devices at the sub or main panel D Protect the Q Aggregator with a maximum 60 amp over current protection device OCPD E Size the AC wire gauge to account for voltage rise Select the correct wire size based on OCPD size and on the distance from the beginning of the Enphase Q...

Page 2: ...an flip the bracket for roof or block mounting When transitioning between rows secure the cable to the nearest rail to prevent cable damage A Install Q Aggregator on rail in a location that does not conflict with the module frame and module mounting hardware Allow a minimum of 1 9 cm 0 75 between the roof and the Q Aggregator Also allow 1 3 cm 0 50 between the back of the PV module and the top of ...

Page 3: ...edures H If all connectors do not show voltage and the main PV circuit from the main panel is active per step D continue with the following troubleshoot ing procedure I Reconnect secure and check all connections All Circuits Appear Non Functioning A Verify that the PV breaker at the main panel reads 240V when measur ing from L1 to L2 B Power off the PV circuit aggregated ac circuit and verify with...

Page 4: ... enter from an uphill direction and that moisture does not enter the Aggregator Water ingress will void the warranty for the Aggregator WARNING Do not expose any connectors to rain or condensation before the connectors are mated WARNING Install the Q Aggregator under the PV module to avoid direct exposure to rain UV and other harmful weather events mount the Q Aggregator off of the roof surface fo...

Reviews: