Section 78
00-02-0997 (web only)
2019-10-07
- 6 -
First-Time Startup
When power is applied to the PV380, the
Warning
and
Shutdown
lights illuminate and the
Murphy logo displays.
On electronic engines only, if a preheat message is being actively broadcast from the Engine
Control Unit (ECU), a
Wait to Start
symbol displays below the Murphy logo as shown in the
next image.
The PV380 will skip the Wait to Start (WTS) screen if the ECU stops transmitting the wait to
start message or if the engine speed is >500 RPM. If the ECU never transmits the wait to
start message, the splash screen is displayed for three seconds after key on, then the main
gauge screen is shown.
Once the engine is running (> 500 RPM), the engine information (electronic or mechanical) will
display on the main gauge screen and additional parameters on the second screen. The
second screen is accessed when the
key is pressed.
NOTE
: For electronic engines, if the ECU does not transmit engine speed (SPN 190)
for the first five seconds after key-on, a warning message
will be displayed and
the amber light will turn on.