The use of the clamps is very important as they guarantee the perfect functioning of the pump
avoiding any leaking which could damage the pump and the people around it.
Should there be any leaked liquid on top of the pump, stop the machine
immediately, remove the plug and clean immediately with a dry cloth.
The pump is absolutely not
suitable to be used in immersion.
Proceed by checking that the switch is in the central “0” position, put plug into the electric socket
and press the switch in the desired priming position. The pump should start priming the liquid
within 20/30 seconds. If this does not happen, make sure that the direction of rotation is the desired
one and that the suction tube is perfectly connected to the suction end-fitting, then, once the pump
has been turned off and the plug disconnected from the mains, check that the clamps are correctly
blocked and that the hose end-fitting are securely fastened with the rings.
During normal functioning the external temperature of the motor can reach
45°C. Therefore a burning sensation may be experienced when touching the machine. Avoid
blocking the motor air suction grid as this would cause the motor to overheat.
2.4 STOPPING THE MACHINE. Once you have finished pumping, turn off the pump. The body of
the pump does empty itself so it is not necessary to refill the body of the pump before turning it
back on again.
Once the pumping operation is complete, if the machine is not to be used again, wash the pump
body by simply pumping fresh water. Thus the machine is kept in perfect mechanical and hygienic
conditions. Then, once the machine plug has been disconnected from the mains, remove the tubes
and connections and remove all liquid from the pump body and dry.
The moving parts require no lubrication: do not introduce oils or greases inside the body of the
pump as these could damage the pump and cause malfunctioning.
Pump attachments should be lubricated to facilitate the assembly of the hose fittings and avoid
seizures.
all repair work must be executed directly by Enoitalia srl or by qualified and
specialized personnel
In case of any repair work, only the original exchange parts must be used which can be obtained by
contact the reseller or constructor.
PROBLEMS
REMEDIES
Insufficient pumping pressure
Check the state of wear of the impeller
Check that there are no obstructions in the
suction tube.
Leaking from the pump body
Check and if necessary replace the rings used to
secure end fittings.
No pump suction
Check the correct direction of rotation of the
pump
Check that hose clamps are tightly fastened.
Check that the priming height is not too high and
if necessary move pump closer to the liquid.
WARNING !
WARNING !
WARNING !
3. CLEANING, MAINTENANCE, RESTARTING
4. POSSIBLE CAUSES OF MALFUNCTION