DOWNLOAD
: set dipswitch 1 OFF and 2 ON
• close the cover on the key and insert it into the connector on the controller
• press the button and check the signal on the LED: red for a few seconds, then green, indicates the correct
completion of the operation.
Different signals or the LED flashing indicate that a problem has occurred: see the corresponding table.
• At the end of the operation, release the button; after a few seconds the LED goes off.
• Unplug the key from the controller.
(KEY)
SUMMARY OF THE BUTTONS
MATERIAL SUPPLIED with code CM00005639 e CM00005640
Pcs 1 NTC015HP00 SENSOR (10Kohm at 25°C) with range of measurement (–50T100°C in air) (-
50T50°C in fluid), 0.1K resolution
Pcs 1 PST00LR400 TERMINAL
SPARE PARTS
CODE
DESCRIPTION
PART NUMBER
KM1
mini contactor 3/4KW 0202925CEL
AP2
level relay
0100725AXX
AP1
control board
6500210AXX
ST1
sensor NTC
NTC015HP00
AP3
terminal
PST000LR400 o PST00LR200
term. connection cable. PSTCONN00300
Document revisions
39
Pressed for 1sec.
Light On/Off
luce
Pressed for 5 secs.
Unit On/Off
Set
parameters
(increase)
No
No
Set parameters
(decrease)
Pressed for 1sec.
display and/or set
the set point
No
Summary of Contents for City line
Page 2: ... Gran buffet Music City line Drop in 2 ...
Page 70: ...70 ...