USER MANUAL
TCM 410J
–
Transceiver Module
© 2022 EnOcean | www.enocean.com
TCM 410J User Manual | v2.3 | June 2022 | Page 16 / 46
2.8.1
Persistent Repeater settings
TCM 410J supports storage of the Repeater settings either in volatile memory (lost upon
power cycle) or in non-volatile memory (maintained upon power cycle). The selection be-
tween these two options is made using the STORAGE_TYPE field of the CO_WR_REPEATER
command shown above.
2.9
Smart Acknowledge
TCM 410J provides a postmaster function with 10 mailboxes for sensors using Smart Ack
technology.
When teaching-in a device using Smart Acknowledge please take care to switch
off all TCM 4xyJ devices which are not continuously powered. Otherwise, these
TCM 4xyJ modules could be declared postmaster. As soon as the power supply is
switched off, a postmaster would be missing and Smart Acknowledge would not
work any longer!
2.10
Remote Management
TCM 410J provides a transparent radio channel also for remote management messages
with a message length of up to 256 bytes. This enables an external micro controller con-
nected to TCM 410J to handle remote management request from external devices or to
control other devices via remote management.