USER MANUAL V1.01
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax +49.89.67
34
689-50
[email protected]
www.enocean.com
Subject to modifications
PTM 240C User Manual V1.01
September 26, 2008 4:13 PM
Page 10/11
PTM 240C
3.2
Transmission Range
The main factors that influence the system transmission range are:
Type and location of the antennas of receiver and transmitter
Type of terrain and degree of obstruction of the link path
Sources of interference affecting the receiver
“Dead” spots caused by signal reflections from nearby conductive objects
Since the expected transmission range strongly depends on these system conditions, range
tests should categorically be performed in early project phases!
The following figures for expected transmission range are considered by using the PTM
240C radio transmitter module and the TCM2xyC radio transceiver module with mounted
whip antenna and may be used as a rough guide only:
10 m
in industrial applications with metal in the vicinity
30 m
for obstructed environment (e.g., through two brick walls inside a building)
200 m
for unobstructed environment (“free field”)
Further notes to determine the transmission range within buildings are available as down-
load from
www.enocean.com
.