background image

 

Setting the Reference Edge of the Instrument for your 
Measurements 

The default setting for the reference edge of the instrument is its 
back edge. This means that any distance measurements you take 
will be referenced to the back edge of the meter. You can choose 
to use the front edge of the meter as the reference edge instead.  

To do so, simply press the 

key, and the next measurement 

will use the front edge as the measurement reference edge. 
Pressing it again will change it back to the back edge. Changing of 
the measurement reference edge will be confirmed by a beep. 
Each time you turn the meter on, the measurement reference edge 
will be set to the default value (back edge). 

 

 
 

Summary of Contents for eD560L

Page 1: ...eD560L Laser Distance Meter User Manual...

Page 2: ...Laser Distance Meter ennoLogic eD560L Made in China User Manual Version 1 2 Revised 11 17 2017 2017 ennoLogic All rights reserved http ennologic com...

Page 3: ...ring Display 5 Switching Measurement Units 5 Setting the Reference Edge of the Instrument for your Measurements 6 Backlight 7 Setting of Power On Defaults and Optional Modes 7 Measurement Modes 8 Dist...

Page 4: ...den You will also find it incredibly useful for many home improvement projects 1 1 Important Notes Safety Considerations and Disclaimer Please Read Please read these safety instructions and this user...

Page 5: ...th strong electromagnetic interference Do not open the instrument other than for the purpose of replacing batteries Store the instrument at a cool and dry location and do not expose it to high tempera...

Page 6: ...tored data indicator 4 Signal strength indicator 5 Secondary display area 6 Main display area 7 Measurement unit 8 Area Volume measurement mode 9 Setting out measurement mode 10 Indirect measurement m...

Page 7: ...Plus key 5 Historical data key 6 Minus key 7 Reference key Backlight key 8 Cancel Power off key 9 Units key 1 4 Battery Installation or Replacement Open the battery cover on the back of the instrument...

Page 8: ...matically after 3 minutes without use Canceling an Operation Clearing Display Press the CLR key to cancel the last operation or to clear the display Switching Measurement Units Press the Unit key to c...

Page 9: ...the meter You can choose to use the front edge of the meter as the reference edge instead To do so simply press the key and the next measurement will use the front edge as the measurement reference e...

Page 10: ...he parameters that can be changed see table below To change the setting for a parameter press the and keys After changing a parameter keep pressing the key until the unit returns to normal measurement...

Page 11: ...s to select whether the backlight turns on automatically at power on od on oFF Use the and keys to enable or disable the outdoor signal enhanced mode Measurement Modes Distance Measurement Press the k...

Page 12: ...nuous measurement mode allows you to determine the maximum or minimum distance such as the measurement of a diagonal distance maximum value or vertical distance minimum value of a room The secondary d...

Page 13: ...ign Any subsequent measurements will now be added to the previous one s Subtraction Take your first distance measurement Then press the key once The first row of the secondary display area will now sh...

Page 14: ...measurement results will be displayed in the secondary display area Adding and Subtracting Multiple Area Measurements After one area measurement has been completed press the or key and take another a...

Page 15: ...the main display area The individual measurement results will be displayed in the secondary display area Adding and Subtracting Multiple Volume Measurements After one volume measurement has been compl...

Page 16: ...ight of a building Indirect Measurement Mode 1 The measurement of distance using the sides of a triangle requires two measurements according to the following steps Press the key once and the icon will...

Page 17: ...s longer than the distance of the right angle edges the calculated length of the third triangle side will be displayed in the main display area The measurement values of the hypotenuse and right angle...

Page 18: ...ard Press the key again to measure the common right angle side of the two triangles Keep the instrument as horizontal as possible Press the key a third time to measure the hypotenuse of the second tri...

Page 19: ...16 measurement values of the hypotenuse and right angle sides a b and c will be displayed in the secondary display area...

Page 20: ...be displayed Follow the prompt of the flashing icon Press the key once to measure the hypotenuse of the first triangle Press the key again to measure the common side of the two triangles Press the ke...

Page 21: ...the secondary display area Note when measurements are made in the Pythagorean mode the length of the right angle side must be less than that of the hypotenuse Otherwise the instrument will display a c...

Page 22: ...lected digit moves one place to the right and finally cycles back to the first digit After you finished entering the value of a press the key again to start setting the value of b After value b has be...

Page 23: ...st setting out point is less than 0 1m 0 33ft the meter begins to beep As the setting out position is approached the sound of the beeper changes noticeably The distance of the setting out point is a b...

Page 24: ...measurement will automatically be added to the end of the data buffer at storage location 20 All other values will be shifted down by one storage location towards 1 so that the buffer always contains...

Page 25: ...Class II Laser type 620 670nm 1mW Calculation of area and volume Measurement with Pythagorean Theorem Adding and subtracting measurements Maximum minimum value measurement Continuous measurement Back...

Page 26: ...r off 3 minutes Size 116 x 56 x 32 mm 4 6 x 2 2 x 1 3 in Weight 100g 3 5oz Failure Causes and Solutions Error Code Causes Solution Calculation error Measure again The received signal is too weak and t...

Page 27: ...d to inaccurate measurements Inaccurate measurements can also result if the target surface reflects light strongly Very dark surfaces or surfaces that do not reflect light well can cause longer measur...

Page 28: ...25 ennoLogic com PO Box 25207 Eugene OR 97402...

Reviews: