background image

 

河北省廊坊市经济技术开发区华祥路 106    

邮编:065001

 

No.106 Huaxiang Road, E&T Development Zone,Langfang 065001 P.R.China   

 

1. OBJECTIVE 

The purpose of this procedure is to provide installation instructions for EST SERIES thin film solar 
module  for field installation. 

2. SCOPE 

This procedure establishes the key installation requirements to mount EST SERIES thin film solar 
modules  in the field which includes, but is not excluded to, roof tops, solar farms, and commercial 
buildings.   

3. RESPONSIBILITY 

ENN Solar Energy Co. Ltd.

 shall maintain the engineering change control of this product. 

 

End installer of the thin film Photovoltaic (PV) modules is responsible for the design and 
integrity of the mounting structure of the modules.  The PV module manufacturer is responsible 
for the design and structural integrity of the PV modules.  Installation of the PV modules must be 
performed by appropriately trained and equipped installers.   

 
 
Supplier is responsible for maintaining and supporting the bill of materials on the Supplier database. 

4. INSTALLATION 

4.1. 

Unpacking and handling 

The site and personnel must obtain the proper handling and transport equipment to install the PV 
modules.   

4.2. Personnel 

Only trained personnel are to handle, transport, and install the PV modules. Immediate exposures 
to sunlight instantly energize the modules and pose a shock risk.  

4.3. Safety 

It is the responsibility of the supplier to provide adequate safety to its employees while 
performing the procedures.  
 
Under normal conditions, a photovoltaic module may experience conditions that produce more 
current and/or voltage than reported at Standard Test Conditions.  Accordingly, the values of Isc 
and Voc marked this module should be multiplied by the following factors: The multiplying 
factors at conditions of an irradiance of 125 mW/cm^2, AM 1.5 spectrum is 1.19, and at a cell 
temperature of minus 10 deg C for Voc is 0.895 and at plus 75 deg C for Isc is 1.05. 
 

Summary of Contents for EST-110

Page 1: ...ST SERIES SOLAR MODULE ISTALLATION MANUAL Revision Change ECO Originator Approver Date A Wang Xiqiao Tang Qing 06 11 2009 B Wang Xiqiao Tang Qing 22 03 2010 C Wang Xiqiao Tang Qing 24 05 2010 D Sectio...

Page 2: ...ately trained and equipped installers Supplier is responsible for maintaining and supporting the bill of materials on the Supplier database 4 INSTALLATION 4 1 Unpacking and handling The site and perso...

Page 3: ...les 4 5 1 Materials of the mounting structure must be compatible with the PV module rails as to not allow galvanic corrosion to either member PV rail or mounting structure The PV rails are made of gal...

Page 4: ...PV modules and snow loading if applicable to the site It should also be able to withstand seismic loading in the corresponding applicable seismic areas These modules have been evaluated by Underwriter...

Page 5: ...ment Zone Langfang 065001 P R China Figure 1 1 3 X 1 1 m Module Boned rail systems Back View Shadow areas are schematic drawing of boned rail system ENN Solar Energy provides various boned rail system...

Page 6: ...hold a structure with a width of 50 8mm The structure holes diameter 10mm are designed for two bolts size M8 x 1 25 x 65mm to fasten the brackets to a structure 4 6 4 2 The modules have been evaluate...

Page 7: ...ced in a no load state by switching off the DC AC converter or breaking the AC circuit interrupter Plugging and unplugging while under voltage is permitted 4 7 1 5 It is unadvisable to use non tinned...

Page 8: ...7 52 6 05 7 0 mm PV KBT4 6II UR PV Wire 12 7 52 6 05 7 0 mm 4 7 3 2 Cable Preparation Reference Multi Contact MA231 Assembly Instructions 4 7 3 2 1 Use appropriate size and type of UL recognized cable...

Page 9: ...the contact is correctly assembled the white marking on the test pin must be still visible Figure 4 4 7 3 4 2 Screw on the cable gland hand tight with the tools PV MS 4 7 3 4 3 The tightening torque m...

Page 10: ...rming a series connected circuit See Figure 7 The maximum current of fuse for the connected circuit can be found in the section 7 Figure 7 Series connection 4 7 6 2 Parallel To wire the modules in par...

Page 11: ...lug using the stainless steel set screw provided by the lug manufacturer The electrical wiring of the ground circuit should be such that the negative leg of the array circuit shall have the same volta...

Page 12: ...axiang Road E T Development Zone Langfang 065001 P R China Figure 9 Ground Bushing Lug Installation 5 REFERENCES 5 1 Acronyms Definitions PV Photovoltaic TF Thin Film 5 2 Documents Not Applicable 6 ME...

Page 13: ...0 IEC 1000 1 16 1 43 125 3 EST 130 1 3 X 1 1 m 143 111 UL 600 IEC 1000 1 18 1 44 130 3 EST 135 1 3 X 1 1 m 146 113 UL 600 IEC 1000 1 20 1 46 135 3 EST 440 2 6 X 2 2 m 280 200 UL 600 IEC 1000 2 20 2 80...

Page 14: ...106 065001 No 106 Huaxiang Road E T Development Zone Langfang 065001 P R China 8 ATTACHMENTS Not Applicable...

Page 15: ...106 065001 No 106 Huaxiang Road E T Development Zone Langfang 065001 P R China THIS PAGE INTENTIONALLY LEFT BLANK...

Reviews: