Specifications
EN-898X Rackmount Chassis Specifications
Mainboard for factor
follow SSI & ATX 12” x 13” specification
Power Supply
follow SSI (provide 480W Single Power Supply)
LED Indicators
Front Bezel:
Voltage alarm
(Voltage =5V, Beep Alarm LED
Blinking 4.57
-
5.51/ Voltage =12V, Beep Alarm LED
Blinking 11.25-12.7)
FAN fail
(Below 2800 rpm Beep Alarm LED Blinking),
Temperature alarm
(Over 60
℃
and return to 55
℃
Beep
Alarm LED Blinking)
HDD activity
,
Power
,
NIC activity
,
System error
Pre HDD Tray:
Active & HDD status x 1 (twin color LED)
Cooling Fans
8981:4 x internal 80 x 80 x 25mm cooling fans
8982/8983: 4 x internal 80 x 80 x 38mm Easy-swap cooling
fans /3 x rear 40 x40 x 20mm cooling fans
Back Plane
8982:1(2 8983) SCSI Back plane support Ultra 320
Support up to 15,000 RPM SCSI hard disk
Support 1” SCA-2 HDD with ID setting
Drive Bays
Hard Disk Trays
IDE:
8981:4x 1” IDE drive bays
8982: 6 x 1” SCSI drive bays
8983: 9 x 1” SCSI drive bays
FDD
8981/8982:1 standard FDD bay
CD-ROM
8981/8982:1 slim CD-ROM bay and 5.25” drive bay
PCI Slot
898X C01 3 x standard PCI adapter slots
898X D01 6
×
Low-profile PCI adapter slots
898X E01 2x standard PCI adapter slots
Switch
1 Power switch 1 Reset switch 1 ACPI switch
1 NMI switch USB1 USB2
Annunciator
FAN fail, Volt Alarm, TEMP Alarm
Dimensions (W x H x D) 430 x86.7x 674.2mm
Weight
8981:10.5 kg (chassis only) 8982/8983: 12.5 kg (chassis only)
Summary of Contents for EN-898X
Page 3: ...3 8981...
Page 4: ...4 8982...
Page 5: ...5 8983 notice this pictures are just for reference...
Page 11: ...11 as follows aim at the holes holes Affix the tape to the pedestal...
Page 20: ...20 as follows L1 R1 the left fan L2 R2 the second fan L3 R3 the right fan...
Page 23: ...23 898X D01 You can add Low profile PCI cards to this server...
Page 24: ...24 898X E01 You can add two PCI cards to this server...
Page 44: ...44 4 We can update the software if we need to set up new equipment...