37
■
Store the product in a dry and secure environment. Before storage, the product and all
connected compressed air tools should be bled.
■
Ambient temperature below 40ºC.
■
The compressed-air hoses must not be kinked.
■
Protect from dust and direct sunlight.
Transport
Before transporting, observe the following
■
Switch off and unplug the product and then bleed the appliance and all connected
compressed air tools.
■
Allow the product to cool down.
■
Hold the carrying handle
2
. carefully.
TROUBLESHOOTING
NOTE
This appliance is maintenance free. Never open the appliance. The appliance may only be
repaired by an authorised service centre or Customer Service. If one of the faults listed
below occurs, note the following:
◆
Disconnect the appliance from any power supply.
◆
Allow the appliance to cool down and wait a short while for the residual energy to
neutralise.
◆
Ensure that the appliance is in good working condition.
Fault
Solution
1.Appliance does not run
1. Check your power supply. Check that all
cables, fuses and the mains socket are in
working order.
2. Do not use excessively long extension
cables.
3. Do not use the appliance at temperatures
below +5 degrees.
4. Avoid the overheated motor to cool down.
2.Working pressure too low
Check the seals or send to the authorized
service centre to get repaired/replaced if
necessary.
3.Tools do not work
Check the hoses, quick coupler and the tools.
Or send to the authorized service centre to
get repaired/replaced if necessary.
Summary of Contents for 151590.01