background image

this  method  will  always  provide 
inaccurate  readings,  and  should  not  be 
used  if  precise        measurements  are 
required.  Normal  temperature  between 
95.4

o

F and 98.1

o

F (35.2

o

C and 36.7

o

C). 

 

3.

 

The  degree  sign  flashes  throughout  the 
testing process. When flashing stops, an 
alarm  will  beep  approximately  10 
seconds.  The  measured  reading  will 
appear  on  the  LCD  simultaneously.  The 
minimum  measurement  time  until  the 
signal  tone  (beep)  must  be  maintained 
without  exception.  The  measurement 
continues  even  after  the  buzzing 
notification.  So  that  in  order  to  achieve 
better  body  temperature  measurement 
result, recommend to keep the probe in 
mouth and rectum about 2 minutes, or in 
armpit about 5 minutes regardless of the 
beep  sound  and  at  least  30  seconds 
measurement 

interval 

should 

be 

maintained.  
 

4.

 

To prolong battery life, press the On/Off 
Button  to  turn  unit  off  after  testing  is 
complete.  If  no  action  is  taken,  the  unit 
will  automatically  shut  off  after  around 
10 minutes. 

 
 

Summary of Contents for Happy Care

Page 1: ...ghly accurate reading of an individual s body temperature The digital thermometer is intended to measure the human body s temperature in regular mode orally rectally or under the arm and the device is reusable for clinical or home use on people of all ages To better understand its functions and to provide years of dependable results please read all instructions first ...

Page 2: ...by position shown in Figure 2 Close your mouth and breathe evenly through the nose to prevent the measurement from being influenced by inhaled exhaled air Normal temperature between 96 3o F and 99 1o F 35 7o C and 37 3o C b Rectal Use Lubricate silver probe tip with petroleum jelly for easy insertion Gently insert sensor approximately 1 cm less than into rectum Normal temperature between 97 2o F a...

Page 3: ...asurement time until the signal tone beep must be maintained without exception The measurement continues even after the buzzing notification So that in order to achieve better body temperature measurement result recommend to keep the probe in mouth and rectum about 2 minutes or in armpit about 5 minutes regardless of the beep sound and at least 30 seconds measurement interval should be maintained ...

Page 4: ... Cover may result in a 0 2oF 0 1oC discrepancy from actual temperature Remove battery from the device when not in operation for a long time The use of temperature readings for self diagnosis is dangerous Consult your doctor for the interpretations of the results Self diagnosis may lead to the worsening of the existing disease conditions Do not attempt to get measurements when the thermometer is we...

Page 5: ...lly For children who are two years old or younger please do not use the devices orally if the unit has been stored at temperatures over 41 104 5 40 leave it in 41 104 5 40 ambient temperature for about 15 minutes before using it CLEANING DISINFECTION Wipe the thermometer with a soft clean cloth For stubborn stains wipe the thermometer with a cloth that has been dampened in water or in neutral dete...

Page 6: ...han 90 0 F 32 0 C Warm the tip of the thermometer and it should show you a reading if the temperature is above 900 F 320 C Hi Temperature taken is higher than 109 9 F 42 9 C Turn off wait one minute and take a new temperature via close contact and sufficient rest Err The system is not functioning properly Remove the battery wait for 1 minute then put it back If it still shows error please send us ...

Page 7: ... minute or two then dip it into a cup of cold water Your display should show Lo meaning low temperature not low battery or a low temperature reading number this time for example it shows 33 C or 91 F Leave it at room temperature for 30 minutes and try using it again and if it does not show Hi or Lo it will mean you have successfully checked your thermometer and good to go If you find that your rea...

Page 8: ...c circuit board with battery chamber approximately 1 cm slightly less than See Figure 4 4 Use pointed object such as a pen to remove old battery Discard battery lawfully Replace with new 1 5 V DC button type LR41 or SR41 UCC392 or equivalent Be sure battery is installed with polarity facing up See Figure 5 5 Slide battery chamber back into place and attach cover ...

Page 9: ... F 131o F 20 o C 55o C SPECIFICATION Type Digital Thermometer Not Predictive Measure range 90 0o F 109 9o F 32 0o C 42 9 o C o C o F chosen by manufacturer Accuracy 0 2o F 0 1o C during 95 9o F 107 6o F 35 5o C 42 0o C at 64 4o F 82 4o F 18o C 28o C ambient operating range 0 4o F 0 2o C for other measuring and ambient operating range Operating mode Direct Mode ...

Page 10: ... with 3 measurements per day Dimension 13 9 cm x 2 2 cm x 1 2 cm L x W x H Weight Approx 12 grams including battery Expected service life Three years Ambient operating range Temperature 41o F 104o F 5o C 40o C Relative humidity 15 95 RH Atmospheric Pressure 700hPa 1060hPa Storage and transportation condition Temperature 4o F 131o F 20o C 55o C Relative humidity 15 95 RH Atmospheric Pressure 700hPa...

Page 11: ...Ingress Protection Rating IP 27 Classification Type BF All rights reserved Happy Care by Enji info enji prime com www enji prime com ...

Reviews: