background image

Ver. 1

Date of issue: II 2022

Power supply: 2xAA batteries

www.engocontrols.com

Distributor:

QL CONTROLS Sp z o.o. Sp. k.
43-262 Kobielice
4 Rolna St. 
Poland

Summary of Contents for E901RF

Page 1: ...FULL MANUAL E901RF Programmable wireless thermostat ...

Page 2: ... 15 6 2 AUTO mode two schedule types 16 6 2 1 First type schedule 16 6 2 2 Second type schedule 16 6 2 3 Switching between schedules AUTO Mode type 1 and 2 17 6 3 First type schedule programming 18 6 3 1 Default program settings 1 3 18 6 3 2 Choosing and programming user programs 4 9 19 6 3 3 Frost Protection program setting 21 6 3 4Temporary override mode 22 6 4 Second type schedule programming 2...

Page 3: ...tions in force in the given country and in the EU Never try to connect the device other than as described in the manual Before assembly repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure that the terminals and electric wires are not live The device may not be exposed to extreme temperatures strong vibrations or subjecte...

Page 4: ...lly before using the device for the first time The thermostat should use 2xAA 1 5V alkaline batteries Rechargeable batteries are not allowed In the set thermostat transmitter thermostat receiver Product features has 2 types of time schedules possibility to choose hysteresis or built inTPI algorithm maximum minimum temperature limitation two relay types selectable in thermostat settings NO normally...

Page 5: ...k there is not allowed to use thermostat in atmosphere of explosive gases and flammable liquids eg coal dust In case if any of listed dangers occur you have to use additional protection measures anti dust and explosive gases tight cover or prevent their formation Furthermore thermostat can t be used in condensation of water vapor conditions and be exposed to water action 1 4 5 6 7 2 3 Quick Guide ...

Page 6: ...ictabsinas shown in the figure until you feel resistance andtiltthefrontpartofthehousing Separate the front part from the back part in thedirectionshownabove Then fix the back cover to the wall using the supplied mounting screws and the holes provided seeredarrows Using the hinges fold the back and front covers by moving as shown in the picture above 1 3 5 4 2 ...

Page 7: ...01RFset youcanusethethermostatanywhereinthehouseandputitonatable desk etc Tousethebracketproperly see the steps below Placethethermostatinacomfortableandaccessible place see Pleasenote inchapter2 2page5 Mount the bracket on the back of the thermostat with use ofthetwodesignedholes 2 1 ...

Page 8: ...intwodifferentmodes AUTO automatic and MANUAL manual To select a specific mode use the switches on the front of the receiver Thermostat transmitter will communicate with receiver only when both are paired together and receiver s switches are set to ON and AUTO position LEFT SWITCH 1 ON receiver ON 2 OFF receiver OFF RIGHT SWITCH 3 MANUAL Receiver works in manual mode receiver operation state depen...

Page 9: ... left switch is in the OFF position TheorangeLEDlightsup In automatic mode the receiver received a heating cooling signal from the thermostat The receiver was started in manual mode left switch is set to ON and right switch is set to MANUAL TheorangeLEDflashes The receiver was paired but lost communication with the thermostat due to out of range or low battery in the thermostat The receiver starts...

Page 10: ...1FLR 091FLR Fv Fv 2 2 3V 3V 2 x AA 2 x AA 16 5 A OR E901RF E901RF RECEIVER RECEIVER BOILER CONNECTION L N power supply 230V COM NO voltage free output fuse batteries Legend Symbols explanation Pump Valve actuator Boiler Boiler connection Boiler s contacts for ON OFF thermostat according to the boiler s instructions ...

Page 11: ...rthefronthousing payingattentiontotheir polarity The thermostat will start up showing the current software version and then go to the main screen PULL OFFTHERMOSTAT SLIDE COVER PLACE AND SLIDETHERMOSTAT FRONT HOUSING THE LCDWILLTURN ONWHENTHE BATTERIES ARE INSERTED INSERTTHE BATTERIES PAYING ATTENTIONTOTHEIR POLARITY 1 3 2 3 Reset RF Reset RF Reset RF ...

Page 12: ...Mode 12 EconomicMode 13 Coolingstatus 14 Heatingstatus 15 Temperatureunit 16 Room setpointtemperature 17 Temporaryoverride 18 Programnumber Reset M H D Button Function Changetheparametervaluedown Changetheparametervalueup Set the day of the week Set the hour Set the minutes Comfort temperature Economic temperature Holiday mode Programming schedule schedule type selection AUTO mode Back button Conf...

Page 13: ... Day time settings are set using the D H and M buttons Please see steps below how to set time day 1 3 4 2 Press any button to highlight the display Pressing H button set the hour Pressing M button set the minutes Pressing D button set the day 3 ...

Page 14: ... mode The sun icon should be visible on the display Using or buttons set new comfort temperature value The thermostat will return to the main screen and display the actual room temperature Confirm by button or wait until the thermostat will approve your choice itself and display the main screen 3 Comfort Mode in this mode the thermostat is to maintain a constant day temperature When the temperatur...

Page 15: ...the thermostat will approve your choice itself and display the main screen The thermostat will return to the main screen and display the actual room temperature In the economic temperature mode the thermostat is to maintain a reduced night temperature This is to ensure a more economical operation of the heating system when for example you are away from home The economic temperature level is indica...

Page 16: ...chedule type 1 is limited to switching between two setpoint temperatures SUN MOON at full hours time periods When creating a schedule type 2 you must define time and temperature setpoint thermostat will start to maintain given setpoint temperature from given time setting There are three different schedule configurations Two different programs separate program for working days Monday to Friday and ...

Page 17: ... of schedule Confirm by button Thermostat will return to the main screen saving chosen type of schedule timeline will disappear if schedule type 2 is chosen Press and hold PROG button for 5 seconds to enter to the schedule type selection 1 3 2 4 3 6 2 3 Switching between schedules AUTO Mode type 1 and 2 ...

Page 18: ...nfirm by button 6 3 1 Default program settings 1 3 1 3 5 6 4 2 Withinfirsttypeschedulemodethereare9programsavailable Programs0to3arefactory definedprogramsthatcannotbechanged Inthischapteryou will find detailed information on the built in factory programs 1 3 in the E901 These are pre programmed time settings for the comfort and economy temperature that can be assigned to a selected day To set up ...

Page 19: ...ons Confirm by button Using or buttons choose program number 4 From 8 00 to 16 00 set comfort temperature by pressing several times button Use the button several times to set the economic temperature until 8 00 Inordertoprogramyourownscheduleitsnecessarytochooseuserprogram 4 9 becauseonlyuserprogramsareeditable Thenwemustdrawourown timeline using Sun Moon buttons Thermostat will be switching betwe...

Page 20: ...not be edited Programs 4 to 9 are user defined editable One program e g program 4 can be assigned to several days of the week If this program is edited the change affects all days to which given program is assigned to 9 3 The thermostat will proceed to program selection editing for the next day days period Repeat steps 4 8 The thermostat will save changes and return to the main screen ...

Page 21: ...ext day days The thermostat will return to the main screen saving the set program Snowflake icon will appear on the display Frost protection mode program 0 protects heating system against freezing It is recommended to set this program if you are planning a long winter trip or if you do not heat up for a long time The thermostat will maintain a constant temperature of 7 C thus reducing energy consu...

Page 22: ...e we can temporarily override it by new setpoint temperature 1 3 5 4 2 Use or buttons to set the temperature Confirm by button The display will show the hand symbol The overwritten temperature is maintained until the next change forced by schedule Then the hand symbol will disappear from the display and the thermostat will return to the automatic mode ...

Page 23: ...set Using or buttons set the minutes for the time period and then confirm by button Select the week period using or buttons Confirm by button 1 3 5 2 4 3 6 4 Second type schedule programming Exemplary schedule setting for working days and weekend There are three different configurations in a schedule type 1 Two different programs timelines separate program for working days Monday to Friday and sep...

Page 24: ...orarily override it by setting new work mode or setpoint temperature Press any button to highlight the display Confirm by button Using or buttons set temperature setpoint during active AUTO mode The hand icon will be displayed The temperature will be maintained until the next change forced by schedule 1 2 4 3 ...

Page 25: ...ton twice or 3 times if backlight is OFF will disable it and thermostat will go back to appropriate mode To cancel active party mode example 3 3 1 2 2 4 3 1 Hold the button for 3 seconds Confirm by button Comfort setpoint temperature will be maintained for defined number of hours After that thermostat will go back to AUTO mode schedule The thermostat will stop party mode and will return to schedul...

Page 26: ...ollow the steps below Press any button to highlight the display Use or buttons to select duration of the holiday mode in days Press button The thermostat will return to the previous mode Use or buttons to set temperature setpoint which thermostat will maintain for defined number of days Confirm by button 1 3 5 1 3 2 4 6 2 Press and hold button for 3 seconds Confirm by button Confirm by button The ...

Page 27: ...stat To set a PIN code go to parameter P12 please refer to Installer settings section To UNLOCK the thermostat keys follow these steps Pressandhold and buttonsfor3seconds Pressandhold and buttonsagainfor3seconds A lock icon will appear on the screen The buttons on the thermostat have been locked The lock icon will disappear from the screen The buttons on the thermostat have been unlocked 1 1 2 2 3...

Page 28: ...rst prepare the receiver for synchronization If you want to re pair the devices with eachother makesurethatthereceiver is disconnected from the power supply and the switches on it are in the AUTO and ON positions Then connect the receiver to the power supply and wait for the green diode to glow continuously Move the left switch to the OFF position and back to the ON position with a quick motion Th...

Page 29: ...eceiver the symbol of the blinking antenna and started the countdown with the number 10 min The pairing process may take up to 10 minutes 10 11 8 9 When the green diode on the receiver lights up continuously the devices have been paired on a new frequency WARNING If the green diode on the receiver has not stopped blinking after 10 minutes repeat the pairing process taking into account the distance...

Page 30: ...that the radio transmission between devices has to be tested before mounting the thermostat to the wall The test can be performed by changing the set temperature i e by activating or deactivating the heating 7 1Transmission test 1 2 3 5 4 Check that the thermostat is not sending a signal to heat Press any button to highlight the display Press button to enter comfort temperature mode The sun icon s...

Page 31: ...ds The flames icon should stop animating If the orange LED does not turn on off as indicated by the transmitter flame icon try moving the transmitter closer to the receiver and repeat all steps from the beginning If it still doesn t work try the pairing process again Check that the orange LED on the receiver is on If so it means that the communication between the devices is correct and the orange ...

Page 32: ... for Electrical Heating P03 Display temperature resolution 0 5 C This parameter specifies the accuracy of the displayed measured temperature 0 5 C 0 1 C P04 Offset temperature 3 5 C to 3 5 C If the thermostat indicates wrong temperature you can correct it by 3 5 C 0 C P05 Relay type NO Normally Open type of relay NO NC Normally Closed type of relay P06 Clock format 24h 24 hour 24h 12h 12 hour P07 ...

Page 33: ...PIN Code NO Disabled NO PIN Enabled P12 Require a PIN to unlock the keys every time NO Functiondisabled NO YES Functionenabled CLR Clear settings factory reset NO Noaction NO YES FactoryReset Only for E901RF thermostat SYNC Pairing function with RXRT510 receiver SYNC NO Pairingdisabled NO YES Pairingenabled ...

Page 34: ...thermostat will restore the default settings 10 Clear settings factory reset 9 User settings reset 1 2 Press any button to highlight the display Use or buttons to move to CLR parameter Confirm the new parameter value with the button Press and hold button for 5 seconds 3 4 Please note 3 Do not use a pencil to press the reset button as the graphite build up on the stylus can short circuit and damage...

Page 35: ...or repairs could only be carried out by ENGO Controls or their appointed agents 11 Cleaning and Maintenance Transmitter s power supply 2 x AA batteries Receiver s power supply 230V AC 50 Hz Rating max 16 5 A Output signal NO COM relay Temperature range 5 35 C Display temperature accuracy 0 1 C or 0 5 C Control algorithm TPI or Hysteresis 0 25 C and 0 5 C Communication Wireless 868Mhz Dimension mm ...

Page 36: ...ility for breach of this warranty by repairing or replacing the defective product This product includes software that matches the distributor s identification at the time of sale The manufacturer distributor provides a guarantee covering all functions and specifics of the product in accordance with this marking The distributor s warranty does not cover the correct operation of the functions and fe...

Page 37: ......

Page 38: ...Ver 1 Date of issue II 2022 Power supply 2xAA batteries www engocontrols com Distributor QL CONTROLS Sp z o o Sp k 43 262 Kobielice 4 Rolna St Poland ...

Reviews: