![Englefield TRADE SERIES Installation Manual Download Page 7](http://html.mh-extra.com/html/englefield/trade-series/trade-series_installation-manual_2413127007.webp)
-7-
1199135-A02-B 07/09/2012
On metallic finish shower, seal
joint between Corner Post and
Door Jamb.
Seal up to the PVC gasket
joints between Return Panel &
Corner Post and Return Panel & Wall
Retainer.
SEALANT APPLICATION STEPS
PART TWO
SEALANT APPLICATION
Ensure all joints are clean and dry
before applying sealant.
(b) Hold the tube at 45
O
angle and
push forward as sealant fills the joint.
(c) The surface of the sealant can
be smoothed (before surface dries)
by using a gloved finger dipped in
a small quantity of water with one
drop of washing liquid added.
(d) Excess sealant should be
removed immediately with a damp
cloth.
CAUTION: Avoid contact with skin,
eyes and mouth and avoid breathing
vapour. If in eyes, immediately flush
with water. If irritation persists, seek
medical attention. Keep out of reach
of children.
IMPORTANT
SIKASIL NG SEALANT SHOULD BE AP -
PLIED TO ALL OUTSIDE JOINTS.
DO NOT SEAL FROM INSIDE.
2a.
Seal full height the joint
between the Walls and the
Wall Retainers.
b.
Seal joint between the Door
Sill, the Return Panel and the
Shower Tray.
IMPORTANT
ALLOW 24 HOURS FOR SEALANT AND
ADHESIVE TO CURE BEFORE USING THE
SHOWER.
d.
To a height of 100mm, seal
joints between Door Frame &
Corner Post and Door Frame & Wall
Retainer.
c.
(a) Cut tip of silicone tube nozzle
at 45
O
angle.
1.
(e) Allow the silicone 24 hours to
cure before using the enclosure.
6mm
45°
For sealant application, follow steps
(a)
to
(e)
detailed below .
e.
INSTALLATION COMPLETE