44
IMPORTANT!
READ AND FOLLOW
ALL
INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
WIRING DIAGRAM
Caution – Shock Hazard
Press the “Off” button and let the appliance completely cool BEFORE
unplugging the appliance and beginning any maintenance or component
replacement.
Risk of shock if appliance is not unplugged before service.
PU-CB19
Control Board Diagram
Hopper
Lid
Safety
Switch
‐
This
unit
is
also
equipped
with
a
hopper
lid
safety
switch
(Part
#
AC
‐
HLSB)
which
is
directly
connected
to
the
auger
motor.
In
the
event
the
hopper
lid
is
left
open
while
the
stove
is
in
operation,
the
hopper
lid
switch
will
prevent
the
auger
from
turning.
This
is
to
prevent
byproducts
of
combustion
from
entering
the
home
through
the
open
hopper
lid
and
also
to
simply
prevent
operation
with
the
hopper
lid
open.
Improper
hopper
lid
safety
switch
operation
will
result
in
an
auger
that
will
not
turn
and
therefore
a
stove
that
will
not
burn.
NEVER
place
your
hand
or
any
object
near
the
auger
while
the
stove
is
connected
to
power.
Summary of Contents for 25-CBEP
Page 60: ......