background image

Lead Volume

Volume control for the Lead channel (pre-FX Loop, influences the send level). Use this knob to dial in the 
desired balance of levels between the Lead and Clean channels. 

Gain Lo/Hi

When you press this button, the input sensitivity of both channels is increased. The Hi-Gain function actually 
turns Clean into a „Crunch“ channel, and Lead into a „Heavy Lead“ channel. It can also be activated via a 
suitable footswitch; the Gain Lo/Hi button is automatically disabled when you connect a footswitch. The 
yellow LED illuminates to indicate „Hi-Gain“ mode is active. 

Clean/Lead

Channel selector push-button for Clean and Lead modes, red LED indicate Lead mode; This function can also 
be activated via the respective footswitch connected. Once a footswitch is connected, the channel selector 
push-button is deactivated. 

Master A

Master A volume knob. Located post effect loop, it controls power amp output. The red LED to the right of 
the knob lights up to indicate Master A is enabled and determining the master level.
You can switch between and using a ENGL Z9 connected to the S.A.C. Port or a footswitch connected to the 
TRS footswitch inputs.

Master B

Master B volume knob. Located post effect loop, it controls power amp output. The green LED to the right of 
the knob lights up to indicate Master B is enabled and determining the master level.

Stand By

Power amp standby switch: Use this switch to silence (0 position) the amp when you take longer break. 
The amp‘s tubes stay nice and toasty, and the amp is ready to roll immediately when you ramp it back up 
to full power. The standby switch is also well-suited for muting the amp for brief breaks, for instance when 
you‘re switching guitars. 

Power

Mains power on/off.

Please note: 

ensure that the Stand By switch is set to Stand By (0 position) before you switch the amp 

on. Let the tubes heat up for about 30 seconds before you activate the power amp. This procedure spares 
the tubes.

Summary of Contents for Screamer 50 II Combo E330II

Page 1: ...E330II Screamer 50 II Operator s Manual...

Page 2: ...onal features Within this brand new fantastic combo amplifier the Screamer 50 Mark II I have packed some clever and useful ideas that offers you a broader spectrum of tonal palettes like the Mid Boost...

Page 3: ...master volume Master A B and an adjustable switchable FX loop parallel serial There are few more handy features to rave about The Screamer amp sports our Serial Amp Control Port or S A C Port for sho...

Page 4: ...and by extension the preamp signal s saturation Soft Lead Gain Lo Hi button disengaged Heavy Lead Gain Lo Hi button engaged CAUTION Extremely high gain and volume levels in the Lead channels can produ...

Page 5: ...ct loop it controls power amp output The red LED to the right of the knob lights up to indicate Master A is enabled and determining the master level You can switch between and using a ENGL Z9 connecte...

Page 6: ...ontroller is a custom tool designed to switch every amp feature designated as foot switchable in this manual To learn if a given feature may be controlled remotely refer to its description herein Head...

Page 7: ...ired with either Gain Lo Hi or Master A B There are four options to enable or automatically assign the Mid Boost feature 1 Mid Boost off for all settings of the amp channels gain levels master the Mid...

Page 8: ...ob is set to Dry the amp signal is routed through with no processed signal 0 Wet balance added to the mix Twist the knob clockwise to blend in the processed signal parallel passive wet balance 1 99 de...

Page 9: ...inet connected to the 16 Ohm jack Summary 16 Z connected to 16 Ohm output 6 An 8 Ohm cabinet connected to one of the 4 Ohm jacks in combination with a 16 Ohm cabinet connected to one of the 8 Ohm jack...

Page 10: ...wer output Power consumption approx 220 Watt 260 VA max Fuses 220 230 240 supply voltage 1 25 AT L T slow blow 100 115 120 supply voltage 2 5 AT L T slow blow Power Tube Fuses 2 x 0 16 AM M medium blo...

Page 11: ...r scouring detergents to clean the amp s housing front or rear panels Use a soft damp cloth or sponge with diluted soapsuds or a standard brand of mild dishwashing liquid instead Never use solvents th...

Page 12: ...at is all channels whose preamp is easily over driven are activated and the following settings are dialed in Gain and or Lead Gain knob past the 12 o clock position Treble knob past the 12 o clock pos...

Page 13: ...rresponding footswitch jacks Are the cords you are using stereo intact and wired properly If you are using footswitches other than an ENGL Z4 or ENGL Z11 are the switches or relays inside the boards o...

Page 14: ...cables The amp or speaker cords may be picking up radio signals for example from activated mobile tele phones or powerful local transmitting stations nearby Switch off mobile phones while troubleshoo...

Page 15: ...4 denotes the button used to enter the setting Column 4 indicates the currently or newly selected configuration For example if LED 3 flashes when the ENGL Z9 s function 2 Setup routine is activated th...

Page 16: ...www engl amps com...

Reviews: