background image

Treble

This is the preamp voicing section´s passive high-frequency EQ for Clean and Crunch I.

Mid Le./Bo. Switch

With this button you can select one of the two mid range controls MID LEAN or MID BOLD. The MID BOLD 
control knob is selected at the activated MID LE./BO. function. The red LED above this button lights up to 
indicate the MID LE./BO. function is on; i.e. the MID BOLD control knob is currently controlling the mid range.
The MID LE./BO. switching function can also be switched via MIDI program change,
MIDI Controller #28, or the ENGL Z9. The red LED above the button lights up to indicate when Contour is 
activated.

A TIP FROM THE DESIGNER: 

I decided to assign different frequency ranges and bandwidths to the two MID 

LEAN and MID BOLD  knobs to give you the greatest possible latitude for shaping sounds as you see fit. In 
practice, this means identical settings on the two knobs yield different tonal results. If you like scooped 
mids, try dialing in lower settings for Clean and Crunch I‘s MID LEAN knob. Set to lower values, this voicing 
control cuts big slices of mids from the sonic pie. Conversely, if you activate MID BOLD, you will boost the 
low mids markedly, which can have a huge effect across the full frequency spectrum of some sounds. These 
two knobs‘ different sound-shaping properties together with the Preshape and Contour button‘s effect on 
voicing give you many different ways of shaping the midrange on the fly using MIDI commands.

Clean Vol.

Volume control for the Clean Channel (pre-FX Loop, influences the send level). Use this knob to dial in the 
desired balance of levels with Channels Crunch I, Crunch II and the Lead Channel. 

Clean Switch

Press this button to activate preamp Clean Channel at the amp. The green LED to the right of  the Clean 
Channel Volume knob lights up to indicate it´s active. The Clean Channel may also be activated via MIDI 
program change, the ENGL Z9, or a conventional 6.3 mm (¼“) TRS dual footswitch.

Crunch I Vol.

Volume control for the Crunch I Channel (pre-FX Loop, influences the send level). Use this knob to dial in the 
desired balance of levels with Channels Clean, Crunch II and the Lead Channel. 

Crunch I Switch

Press this button to activate preamp Crunch I Channel at the amp. The yellow LED to the right of  the Crunch 
I Channel Volume knob lights up to indicate it´s active. The Crunch I Channel may also be activated via MIDI 
program change, the ENGL Z9, or a conventional 6.3 mm (¼“) TRS dual footswitch.

Summary of Contents for E610II

Page 1: ...E610II Savage 120 II E630II Savage 60 II Operator s Manual...

Page 2: ...nce some of the proven features to a top notch level Furt hermore I equipped these superb amps with a few new features like two mid range control knobs for main channel I that gives the player additio...

Page 3: ...tivated the level in Channels Clean and Crunch I gets boosted for approx 10 dB The level in Channels Crunch II and Lead I gets boosted for approx 4 dB A TIP FROM THE DESIGNER use this feature to reduc...

Page 4: ...und option can also be switched via MIDI program change MIDI Controller 27 or the ENGL Z9 The red LED above the button lights up to indicate when CONTOUR is activated A TIP FROM THE DESIGNER in a cert...

Page 5: ...D BOLD you will boost the low mids markedly which can have a huge effect across the full frequency spectrum of some sounds These two knobs different sound shaping properties together with the Preshape...

Page 6: ...ight those cherished tubes are the culprits The Noise Gate is a tool that lets you silence this noise during breaks by way of signal mute circuit Note that electric guitars pick up interference signal...

Page 7: ...ob determines the power amp s high frequency response when is activated The green LED next to the knob lights up to indicate Presence B is active Input Jack 6 3 mm unbalanced input jack Plug your guit...

Page 8: ...h II and Lead Middle This is the preamp voicing section s passive midrange frequency EQ for Crunch II and Lead Treble This is the preamp voicing section s passive hi frequency EQ for Clean Crunch II a...

Page 9: ...act duplicate of an existing preset The system will select a WRITE operation whenever you edit a MIDI preset that is when you have modified a programmable feature You ll know that this is the case bec...

Page 10: ...he master level FX Loop I II Switch This button switches to and from between FX Loop I and FX Loop II The red LED above the button lights up to indicate is on You can also select loops via MIDI progra...

Page 11: ...et the Stand By switch to the 0 position Power Switch Mains power on off PLEASE NOTE ensure that the Stand By is set to Stand By 0 position before you switch the amp on Let the tubes heat up for about...

Page 12: ...evice always make sure that the ENGL MIDI Footcontroller Power Supply switch is set to the right to avoid damaging the device ENGL Midi Footcontroller Power Supply This selector activates a MIDI In po...

Page 13: ...ting the small switch labeled 6 to ON enables the MIDI controller access capability for certain Amp functions Setting the small switch labeled 6 to OFF disables the MIDI controller access capability f...

Page 14: ...t is disabled when the Z9 is connected CAUTION Connect only the ENGL Z9 to this 6 3 mm stereo jack Connecting any other switching device may damage it and or the amp s circuitry Footswitch Clean Crunc...

Page 15: ...wet balance 1 99 depending on knob position When the knob arrives at the Effect position only the wet signal that is the processed signal generated by the connected effect device is patched to the po...

Page 16: ...oss of a power tube results in an unbalanced signal Be sure to have a specialist look over the power amp as soon as possible the fuse probably blew because of a defective power tube Once a fuse has bl...

Page 17: ...ne of the 4 Ohm jacks in combination with a 16 Ohm cabinet connected to one of the 8 Ohm jacks Summary 8 Z 16 Z connected to 4 ohm 8 ohm output NOTE Never operate the power amp without a sufficient lo...

Page 18: ...T L T slow blow E610II Power Tube Fuses 2 x 0 16 AM M medium blow E630II 2 x 0 315AM M medium blow E610II Important Replace these with fuses oft he same type and rating only Tubes V1 ENGL ECC83 First...

Page 19: ...cooling which increases component life Never operate the amp without an adequate load a speaker cabinet or suitable terminating resistor High ambient temperatures place an additional strain on diverse...

Page 20: ...clock position This type of configuration can cause considerable feedback that could well damage your hearing and de stroy speakers If you set the Volume or Master knobs to higher volume levels always...

Page 21: ...switches continuously connect to GND when you wish to activate the given function If you re unsure about the answers to these questions consult an authorized service centre or a professional specialis...

Page 22: ...hts up F1 4 Function 1 1 Channel 1 LED 1 flashes F1 5 Function 1 Gain Lo Hi 1 Channel 2 LED 2 flashes F1 6 Function 1 Bright 1 Channel 3 LED 3 flashes F1 7 Function 1 Noise Gate 1 Channel 4 LED 4 flas...

Page 23: ...y Stereo 6 3 mm plug Stereo 6 3 mm plug Very important use a stereo plug only Custom Z 9 Footswitch only Serial Amp Control Port Dual Footswitch ring Data tip 5 Volts ring Sub I II tip CHI CHII Error...

Page 24: ...www engl amps com...

Reviews: