12
Installation Procedure (cont’d)
Step 6 - Route the thermocouple wire
a.
Plug the thermocouple extension wire into the thermocouple and route to the BPM. Do not cut the ther-
mocouple extension wire. Plug the thermocouple extension into the BPM.
Step 5 - Assemble and route the Synflex backpressure sampling tube
a.
Measure and cut the appropriate length of Synflex tube to go from the end of the stainless steel tube to
the condensation trap. Cut the ends square and clean to ensure proper sealing when assembled.
b.
Locate the brass tube inserts and press into each end of the synflex tube
c.
Locate the 1/4” swage to 1/4” swage fitting
d.
Connect one end of the fitting to the stainless steel tube. Tighten compression nut finger tight and then
tighten one full turn with a wrench
e.
Slide one end of the synflex tube into the fitting. Tighten compression nut finger tight and then tighten
one full turn with a wrench.
f.
Route the synflex tube to the condensation trap and slide the tube into the inlet fitting. Tighten com-
pression nut finger tight and then tighten one full turn with a wrench.
ATTENTION
Do not cut or shorten the thermocouple extension wire.
CAUTION
Be careful not to lose the small brass tube inserts.
ATTENTION
Route wires with existing wire harnesses and keep away from hot surfaces. Wire
loom is recommended but not provided.