background image

WARRANTY:

 

This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period

of one (1) year from the date of sale to the original consumer customer.  SECO-LARM’s obligation is limited to the repair or replacement of any

defective part if the unit is returned, transportation prepaid, to SECO-LARM.

This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or

abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes

other than defects in material and workmanship.

The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option.   In no event

shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

NOTICE:

   

The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one

of continual development and improvement.  For this reason, SECO-LARM reserves the right to change specifications without notice.

SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2015 SECO-LARM U.S.A., Inc.  All rights reserved.  This material may not be reproduced or copied, in whole or in part, without
the written permission of SECO-LARM.

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

®

 U.S.A., Inc.

 U.S.A., Inc.

 U.S.A., Inc.

 U.S.A., Inc.

 U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA  92606

Tel: 800-662-0800 / 949-261-2999   Fax: 949-261-7326

PITSW1

Website: www.seco-larm.com

E-mail: [email protected]

FILE: DT/DTP/MiSK9x9TDWS-BQ_150205.pmd

ORDER PART# 762-103-2%

Battery

Battery Operated 12VDC Output

Adapter

Power on

Transmission

Push-Button

or contact

12VDC Alkaline

battery included

12VDC output

adapter is optional

Example Connection Diagrams:

12VDC

Adapter

INSTALLATION:

1.) Power Connection 

 The wired transmitter can be

powered by the factory preinstalled one 12VDC
alkaline battery or by an external 12VDC output
regulated adapter (not included).
If an external power adapter is preferred, connect
the red & black wires of the wired transmitter to the
adapter’s output wires.  Must observe correct wire
polarity.  Red wire is for positive and black wire is
for negative.

NOTE: a) The power input range of the wired

transmitter unit is between 9~13.8VDC,
connecting more than 13.8VDC power or
reversing the polarity will burn out the unit
and void the warranty.

b) Use only 12VDC output “regulated” adapters

to power the wired transmitter.

c) Factory had preinstalled one 12VDC alkaline

battery inside wired transmitter unit.  If it is
necessary to connect an external adapter,
removed first the internal alkaline battery,
otherwise the internal battery will become
defective.

2.) External Switch 

Connection –

 Aside from its own

built-in single button, the wired transmitter can also
be controlled by an external N.O. pushbutton / sensor
switch (not included), or use both the built-in &
external switches (see Example Connection Diagram
below).  If an additional external N.O. switch is
necessary, connect the two blue wires to the switch
terminal.

NOTE: If the red & black or the two blue wire pairs are

not being use, the tip of the wires (where the
copper wires are exposed) must be cut or
wrapped to avoid a short circuit.