ENFORCER 50ft Large Reflective Beam Sensor
8
SECO-LARM U.S.A., Inc.
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
WARRANTY:
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is
not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
SECO-LARM
®
U.S.A., Inc
.
16842 Millikan Avenue, Irvine, CA, 92606
Website: www.seco-larm.com
PITSW3
Phone: (949) 261-2999 | (800) 662-0800 Email: [email protected]
MiE-931-S50RRLQ_1312.docx
Troubleshooting:
Sensor does not detect the object.
•
Check the sensor’s alignment.
•
Readjust the sensor’s response time.
Alarm LED will not turn ON when the beam
is interrupted
•
Clean the sensor and reflector with a damp
(not wet) cloth.
•
Adjust the reflector and/or sensor for proper
alignment.
Alarm LED turns ON when object is
detected, but there is no output
•
Check wiring between the sensor and local
alarm device.
Alarm LED is continuously ON
•
Check the sensor’s alignment.
•
Check for any objects between the sensor
and reflector that may be causing false
alarms.
Alarm output becomes erratic in bad
weather
•
Check the sensor’s alignment.
•
Readjust the sensor’s response time.
Frequent false alarms from leaves, birds,
or other objects
•
Readjust the sensor’s response time.
•
Change the sensor’s location.
This product is protected by the following patents: U.S. pat. no. D485774 Taiwan pat. no. 89463 China pat. no. ZL03311103.0
Other international patents are pending.
Note: Model numbers that end with “Q” or that have a round green “Q” sticker signify RoHS-compliant products.
E-931-S50RRLQ
50ft Large Reflective Beam Sensor
Manual
•
Up to 50ft (15m) sensing range
•
Weatherproof (IP55)
•
Beam status LED
•
12~250 VAC/VDC Operation
•
Form C relay rated 0.5A@120VAC
•
N.C. Tamper switch rated 0.5A@30VDC
Patented