eNet Server

With some routers, the host name of the router must also be entered, e.g. eNet-
Server.fritz.box.

The log-in window of the commissioning interface is opened in the web browser.

Log into the commissioning interface

Enter your username and password.

For first log-on, enter "admin" both as the username and password. For security reasons,
change the password after this.

Select Anmelden.

For trouble-free data transmission a wired connection via LAN is recommended.

Legal Notice

This product incorporates open source software components covered by the terms of third party
copyright notices and/or license agreements. The technical documentation of the eNet server
contains detailed information on this.

6

Technical data

Rated voltage

DC 12 V SELV

Current consumption

400 mA

Power consumption
Operation

max. 6 W

Standby

max. 2 W

Ambient temperature

-5 ... +45 °C

Storage/transport temperature

-20 ... +70 °C

Relative humidity

20 ... 70 % (no moisture condensation)

Protection class

III

Fitting width

108 mm / 6 HP

Connections
Supply

device connection terminal

LAN

RJ45-socket 8/4-pin

WLAN antenna, external

SMB socket

Bus line
Cable length

max. 3 m

RMD channels
Number

max. 32

IP communication
LAN

Ethernet 10/100 MBit

WLAN

2.4 GHz, IEEE 802.11g

IP connections

max. 8

eNet communication
Radio frequency

868.0 ... 868.6 MHz

Transmitting range in free field

typ. 100 m

Transmission capacity

max. 20 mW

Receiver category

2

6 / 7

32580552

10864944

01.02.2022

Summary of Contents for GIRA

Page 1: ...top and emergency call These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Front view eNet server 1 Slide for retaining the antenna cable 2 Buttons for manual operation and restart 3 LEDs 4 Voltage supply connection 5 Data cable connection 6 Socket for external eNet antenna 7 RJ45 socket for Ethernet connection 8 Socket for exte...

Page 2: ...r software version 2 0 Signalling The table below provides an overview of the signalling via LEDs of the eNet server Labelling Colour of the LED Function POWER green Flashes eNet Server starts Illuminated eNet server ready for operation J green eNet radio transmission active SCAN green Scan operating mode active LAN green Ethernet connection active WLAN green WLAN connection active 4 Operation Ope...

Page 3: ...ers and passwords are reset to factory setting A restart of the eNet server is per formed The POWER LED flashes during the restart and illuminates when the eNet server is ready for operation For first log on enter admin both as the username and password For security reasons change the password after this Delete project Press the RESTART button 13 for longer than 4 seconds The POWER J and SCAN LEDs...

Page 4: ...n height in the distribution board is maintained Fitting the device Observe the temperature range Ensure adequate cooling Mount device on DIN rail with the terminals facing downwards facing downwards Connecting the device Figure 3 Connection diagram Use a suitable bus line e g J Y St Y 2x2x0 8 Connect the device according to the connection diagram Figure 3 Unfavourable installation conditions make...

Page 5: ...rnal antennas are connected Connection via IP address of the eNet Server Precondition The eNet SMART HOME app is installed on a smartphone The smartphone is connected to a WiFi router The IP address of the eNet server can be found on the Home page and in the System menu of the app Set up the network connection between the eNet Server and the computer via the Wifi router Start web browser Enter the...

Page 6: ...reements The technical documentation of the eNet server contains detailed information on this 6 Technical data Rated voltage DC 12 V SELV Current consumption 400 mA Power consumption Operation max 6 W Standby max 2 W Ambient temperature 5 45 C Storage transport temperature 20 70 C Relative humidity 20 70 no moisture condensation Protection class III Fitting width 108 mm 6 HP Connections Supply dev...

Page 7: ...cialist trade Please submit or send faulty devices postage paid together with an error description to your re sponsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center 10 Additional information You can find a Quick Start Guide as an introduction to working with the eNet Server product documentation for working w...

Reviews: