Page 6
Product Specification Manual - Destination 1.9
ENGLISH
1. General Information
1.1
Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Models
Destination 1.9 (EB00066)
Type of combustion
Non-catalytic
Fuel Type
Dry Cordwood
Recommended heating area (sq. ft..)
1
250 to 1,200 ft
2
(23 to 111 m
2
)
Nominal firebox volume
1.2 ft
3
(0.034 m
3
)
Loading volume EPA
1.03 ft
3
(0.0292 m
3
)
Maximum burn time
1
7 hours
Overall heat output rate (min. to max.)
2 3
8,471 BTU/h to 32,293 BTU/h
(2.48 kW to 9.46 kW)
Average overall efficiency
3
- Dry cordwood
75 % (HHV)
4
80 % (LHV)
5
Optimum efficiency
6
82 %
Optimum heat transfert efficiency
7
78 %
Average particulate emissions rate
8
1.5 g/h (EPA / CSA B415.1-10)
9
Average CO
10
34 g/h
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft3 and 20 lb/ft3. Other performances are based
on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft3. The moisture content is between 19%
and 25%.
3
As measured per CSA B415.1-10 stack loss method.
4
Higher Heating Value of the fuel.
5
Lower Heating Value of the fuel.
6
Optimum overall efficiency at a specific burn rate (LHV).
7
The optimum heat transfer efficiency is for the low burn rate and represents the appliance's ability to convert the energy contained in the wood
logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
8
This appliance is officially tested and certified by an independent agency.
9
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14 based on the ATM send by
EPA on October 12th, 2017.
10
Carbon monoxide.