PROTECTION AND AUTOMATIC RESTART FEATURES
Electronic overload protection with automatic shutdown
Built-in internal backup DC fuse
Low battery voltage warning followed by automatic shutdown
High-input voltage protection with automatic shutdown
Output short circuit protection
Energy-efficient cooling fan
Note that the cooling fan will start working only when necessary enabling to save energy.
Overheating protection with automatic shutdown when the inverter exceeds 60° C or when the load capacity exceeds 30 %.
Protect function and Restart work mode
Function
Led light
Alarm
AC output
Restart mode
Input low voltage alarm
Green light on
Red light off
Alarm
working
Alarm stops automatically when the
battery returns to the rated voltage.
Input low voltage
shut down
Green light on
Red light on
No alarm
not working
Inverter will restart automatically
when the battery voltage has reached
the restarting threshold.
LED indicators will show: green light
on, red light off.
Input over voltage
protection
Green light on
Red light on
No alarm
not working
The inverter will restart automatically
when the battery returns to the rated
voltage.
LED indicators will show: green light
on, red light off.
Input over load
protection
Green light on
Red light on
No alarm
not working
The inverter will restart automatically
when the battery returns to the rated
voltage.
LED indicators will show: green light
on, red light off.
Over temperature
shut down
Green light on
Red light on
Alarm
not working
Inverter will restart automatically
when voltage has reduced to the
restarting threshold.
Led indicators will show: green light
on, red light off.
Output short circuit
P.S.: The USB port will work under all protection conditions listed above.
Waste dispose of electronic device
Landfilling e-waste is harmful to the environment as substances such as cadmium, lead, mercury, nickel, plastics and flame retardants can leach out
into the soil and water. These substances can be toxic and have been associated with cancer and neurological disorders in children.
Please dispose this unit at an electronic waste disposal/recycling site.
Green light on
Red light off
No alarm
not working
The inverter will automatically shut
down, remove the short circuit and
restart inverter.
›
›
›
›
›
›