background image

 

 

TP600SERIES 

 INVERTER POWER SUPPLY

 

 
 
 

USER MANUAL

Summary of Contents for TP600 Series

Page 1: ...TP600SERIES INVERTER POWER SUPPLY USER MANUAL ...

Page 2: ...ins important safety and operating instructions Read and keep this User Guide for later reference Before using TP600 read and follow all instructions and caution marking on TP600 the batteries and in all sections of this instruction manual ...

Page 3: ... 2 DC input voltage and operate range 2 3 3 Principle of Design 3 1 3 1 Block Diagram 3 1 3 2 Operation Mode 3 1 3 2 1 AC mode 3 1 3 2 2 DC mode 3 1 3 3 Outline and LED Indicators 3 2 3 3 1 Outline 3 2 3 3 2 Front panel 3 4 3 3 3 Rear panel 3 5 3 3 4 LED indicators 3 6 4 Installation 4 1 4 1 Preparation 4 1 4 1 1 Tool Information 4 1 4 1 2 Ambient Condition 4 1 4 1 3 Connect the Cable 4 1 4 1 4 In...

Page 4: ...wn 5 2 5 2 3 Inaudible 5 2 6 Operation Mode and Status Display 6 1 6 1 LED Indicator and Button Definition 6 1 6 2 LCD Interface 6 2 6 3 Work status 6 2 6 3 1 Standard model 6 2 6 3 2 Professional model 6 5 7 Alarm Remote Control 7 1 7 1 Alarm signal and Error code description 7 1 7 2 Remote control and Alarm 7 2 7 2 1 Communication port 7 2 7 3 Troubleshooting 7 3 ...

Page 5: ... safety standard and are out of the service responsibility 1 2 General Precaution 1 Do not expose TP600 to rain snow or liquids of any type it is designed for indoor use To reduce risk of damage do not block off ventilation or otherwise the INVERTER would be overheating 2 To avoid fire and electric shock make sure all cables selected with right gauge and connected well Smaller diameter and broken ...

Page 6: ...user s manual 1 2 4 Remove personal metal items such as rings bracelets necklaces and watches when working with batteries Batteries can cause short circuit current high enough to make metal melt and could cause severe burns ...

Page 7: ... by input side directly z Selectable input frequency ranges 44Hz 66Hz with output frequency is 50Hz or 60Hz z Auto restart When the utility mains reactivation the unit will restart automatically z Ideal protection function When the system is in abnormal condition or other protection mode like Over Current Protection Over Voltage Protection Over Power Protection and Over Temperature Protection or t...

Page 8: ...put Frequency 50Hz 10 AC Output Voltage 230V 2 Output Frequency 50Hz 0 1 Rated Output Current 1 7A 3 5A 5 2A 7 0A 10 4A 13 9 17 4 13 9 15 2 Power Factor 0 8 0 7 THD 3 Transient Response Load from 0 to 100 less than 30ms Bypass Transfer Time 5ms Overload AC mode 120 3min 150 30sec INVERTER mode 120 30sec 150 10sec Efficiency 88 Protection Overload short circuit overvoltage undervoltage thermal Inte...

Page 9: ...6 136 192 272 DC operated range 10 14 8 20 29 5 40 59 5 91 5 136 183 272 Low warning voltage 11 22 44 101 202 Notes 1 To protect battery TP600 only powered ON as battery voltage in DC operated range 2 When battery voltage is lower to the level of warning point then audible alarm is start up In case the battery voltage is lower than the limit unit will shut down ...

Page 10: ......

Page 11: ...form of protection for all important data processing and telecommunication applications Block Diagram 3 2 Operation Mode 3 2 1 AC mode That is A operation mode When mains power is normal TP600 works in mains mode or inverter mode in case mains is failure 3 2 2 DC mode That is D operation mode In inverter works all the time in the event of DC failure unit transfers to ...

Page 12: ...Inverter power supply user s manual 3 2 bypass mode 3 3 Outline and LED Indicators 3 3 1 Outline Rack standard model 0 5 1 5KVA 2 5KVA ...

Page 13: ...Inverter power supply user s manual 3 3 Rack professional model 0 5 1 5KVA 2 5KVA ...

Page 14: ...Inverter power supply user s manual 3 4 Tower model 0 5 1 5KVA 2 3KVA 3 3 2 Front panel Rack standard model Rack professional model ...

Page 15: ...Inverter power supply user s manual 3 5 Tower model 0 5 1 5KVA 2 3KVA 3 3 3 Rear panel Rack standard model Rack simplified model Rack simplified model 4 5KVA 48V ...

Page 16: ...Inverter power supply user s manual 3 6 Tower model 0 5 1 5KVA 2 3KVA 3 3 4 LED indicators Standard model Professional model ...

Page 17: ...o vibration and hading angle less than 5 degree z Pollution Class II Working temperature of 20 25 and Humidity of 50 are recommended Caution The INVERTER must be installed in a location with good ventilation far away from water inflammable gas and corrosive agent 4 1 3 Connect the Cable AC input power cord Tower and Rack Standard model use the cord prepared by manufacture but user should prepare t...

Page 18: ... 2 5mm 2 4000VA 5000VA 25 mm 2 10mm 2 4 mm 2 4 1 4 Inspection Unit should be saved on the right environment and the term for preserving is less than 3months Before installation unit should be placed on the spot Unpack the package and check the package contents Keep all spare part and accessories for future use 4 2 Installation 4 2 1 Rack model 1 Install handle Take out two L brackets and handles f...

Page 19: ...ion 1 Connect DC input cable Following battery polarity guide marked on rear panel Place the battery cable over TP600 s DC terminal For the user operation safety cut off the power when install the unit 2 Connect AC input and output Use right cable according to different terminal of rear panel For Standard model take out the cable in accessories plug the cable into the socket of rear panel showed a...

Page 20: ...1 Fix up Install the unit in any protected environment that provided adequate airflow around the unit and is free from water Also place the unit away from the object at least 20cm around the unit 2 Cable Connection Refer to Rack Standard Model Figure as below ...

Page 21: ... and unit will perform self diagnosis Unit is already running in normal mode 5 1 2 General operation z Only press ON OFF button in daily use z Power off loadÆINVERTER z Cut off the DC and AC input power and output load if long term no use z Switch on the unit according to the program of first power on after long term no use 5 2 Operation 5 2 1 POWER ON 1 Make sure the DC input and AC output connec...

Page 22: ...ay Otherwise if all parameters are normal unit will run the normal mode 5 2 2 Shutdown Press ON OFF button and inverter LED is winked 5 2 3 Inaudible In case trouble is shooting during INVERTER is running unit will alarm with beep and alarm LED will light Press inaudible button to be inaudible Press the button continuously for 3sec to turn off the alarm Alarm will be turned on after press for 3sec...

Page 23: ... illuminates when the mains input is normal flashed when abnormal and goes off when it fails Inverter 1 Blue It illuminates when inverter is normal operation Bypass 1 Green It illuminates when unit is on bypass mode Output 1 Green Output is normal DC voltage 4 Green 25 50 75 100 Load capacity 4 Green 25 50 75 100 DC low 1 Yellow It illuminates when DC voltage is lower than limit Overload 1 Yellow ...

Page 24: ... of unit Model name Press Turn page button to change the interface Home page will be hold in long time no changing interface 6 3 Work status illuminate dim flash 6 3 1 Standard model 6 3 1 1 Standby mode In case AC mains input is normal without turning on the unit the LED indicator of mains power is illuminating LED indicator of bypass is flashing and LED indicator of DC shows the capacity ...

Page 25: ...minating DC voltage load show battery capacity and load proportion 6 3 1 3 Inverter mode Inverter LED and output LED are illuminating DC voltage load show battery capacity and load proportion 6 3 1 4 DC low Output LED and DC low LED are illuminating DC voltage load show battery capacity and load proportion ...

Page 26: ...ghting overload buzzer beeps once every 2s with normal output Otherwise buzzer continually beep without output because of heavy overload and troubleshoot LED is illuminating Overload on inverter mode Overload on AC mode Shutdown via overload 6 3 1 6 Troubleshooting Troubleshoot LED is illuminating detailed refer to 7 1 ...

Page 27: ...ing on the unit the LED indicator of mains power is illuminating LED indicator of bypass is flashing press Turn page button to check the parameter 6 3 2 2 AC mode Bypass LED is illuminating press Turn page button to check the parameter 6 3 2 3 Inverter mode Inverter LED is illuminating press Turn page button to check the parameter ...

Page 28: ... show battery capacity and load proportion DC low in Inverter mode DC low in AC mode 6 3 2 5 Overload Overload LED is illuminating in case lighting overload buzzer beeps once every 2s with normal output Otherwise buzzer continually beep without output because of heavy overload and troubleshoot LED is illuminating ...

Page 29: ...n AC mode Overload in Inverter mode Overload Shutdown 6 3 2 6 Troubleshooting Troubleshoot LED is illuminating Shutdown due to overload DC power on DC higher voltage DC power on inverter faulty Shutdown due to short circuited overheating See table 7 1 ...

Page 30: ...Inverter power supply user s manual 6 8 Alarm via DC higher voltage Alarm due to short circuit Alarm via inverter faulty Alarm due to Overheating ...

Page 31: ...Caution DC power ON DC voltage is lower than limit N A Once 5s normal Caution AC power ON DC voltage is lower than limit N A Once 5s normal Warning Standby mode on AC mode with AC and DC higher voltage N A Once 1s normal Warning AC power ON DC voltage is higher than limit N A Once 1s normal Warning AC power ON overload N A Once 2s normal Warning DC power ON overload N A Once 2s normal Troubleshoot...

Page 32: ...ence for the operation unnecessary to take action 3 Caution abnormal and influence the operation of inverter must be solved 4 Warning abnormal and dangerous to avoid inverter faulty must be solved immediately 5 Trouble trouble is shooting and inverter does not operate must be solved immediately 7 2 Remote control and Alarm 7 2 1 Communication port RS232 Dry contact Dry contact signal The inverter ...

Page 33: ... once every 5s the LED of DC low is illuminating but output is normal DC input is abnormal voltage is lower than limit Adjust the DC voltage 4 AC mode buzzer beeps once every 1s the LED of Troubleshooting is flashing but output is normal DC input is abnormal voltage is higher than limit Dangerous higher voltage would damage inverter turn off the unit and check the DC voltage 5 DC mode buzzer beeps...