Overpressure (fireplace) mode

If you are going to light the fireplace, you may need to 

use the overpressure function.

WARNING

WARNING:

 The overpressure mode is primarily 

intended to be used only when lighting the 

fireplace, not for providing supply air to the 

fireplace.

TIP:

 Unnecessary use of the overpressure 

function leads to waste of energy.

To select:

1.  Press the 

Mode 

button for 3 seconds. 

The display shows first briefly text 

on

 and then 

F-PL

.

To return to Home mode:

1.  Press the 

Mode 

button for 3 seconds. 

The display shows first briefly text 

oFF

 and then 

the display returns to the basic view.

NOTE:

 The Overpressure mode is set for 

duration of 10 minutes and can be selected 

maximum 2 times a day. When time is expired 

the system returns to the previous mode.

NOTE:

 The Overpressure mode can be set also 

by an external fireplace push button switch (if 

installed).

Heating mode

The Heating mode uses the built-in heater to warm up 

the supply air. 

To select:

1.  Press the 

Temperature 

button for 3 seconds. 

The display shows briefly texts 

HEAt

 and 

on

 and 

then the display returns to the basic view.

To return to Home mode:

1.  Press the 

Temperature 

button for 3 seconds. 

The display shows briefly texts 

HEAt

 and 

oFF

 and 

then the display returns to the basic view.

NOTE:

 The heater is not used to warm the 

supply air if the outside temperature is over  

+ 25 °C.

Eco mode

Selecting Eco mode for your ventilation system means 

that you allow the system to make slight changes to 

the defined temperature and ventilation values to 

save energy. In Eco mode, the system will not react to 

temperature changes as quickly as in normal mode, 

but waits awhile to see where the temperature is going 

before it starts heating or cooling the incoming air.

This green choice will not significantly affect your 

comfort level, but will save you money.

To select:

1.  Press the 

Eco

 button. 

The display shows briefly text 

ECO

 and then 

on

 

and then the display returns to the basic view. 
The ventilation system adjusts itself to the new 
setting.

To return to Home mode: 

1.  Press the 

Eco

 button. 

The display shows briefly text 

ECO

 and 

oFF

 and 

then the display returns to the basic view.

NOTE:

 The selected Eco mode switches off if 

the outside temperature rises over + 25 °C and 

switches back on when the outside temperature 

sinks below + 25 °C.

USING VENTILATION 

EFFICIENTLY

Properly designed and used ventilation saves money 

and energy. It also promotes the health of both the 

living environment and its inhabitants.

• 

Always operate the ventilation system according 
to the plan specifically designed for your premises, 
throughout the year.

• 

Clean or replace the filters when prompted and 
vacuum the insides of the unit regularly. 

• 

Open the ventilation unit hatch and take a peek 
regularly, for example once a month.

• 

Dust and other impurities in the air can get the 
equipment very dirty. The dirt blocks the filters 
and sticks onto the heat exchanger, which makes 
ventilation inefficient.

• 

Use the special modes, such as Overpressure only 
when really needed. 

• 

Using the special modes unnecessarily increases 
your energy consumption.

Summary of Contents for eWind

Page 1: ...User instructions ENG 25 01 2016 Enervent eWind...

Page 2: ...2 Copyright Ensto Enervent 2016 Unauthorized copying and lending are prohibited Approvals and version history Revision Date Description of change Approved by 0 0 2016 01 25...

Page 3: ...Using ventilation in cold season 8 ENHANCED FEATURES 8 Information view 8 eWind Info list 8 Measurements view 9 eWind Measurements list 9 Service reminder view 9 Time to service 9 Settings view 10 ADJ...

Page 4: ...he primary function of the unit The unit is also used for recovering heat energy from extracted air Depending on the model it can be used for cooling supply air during summertime It can also be used f...

Page 5: ...ure display 3 Mode button 4 Eco button 5 Temperature button Button display Description Mode display Current use mode Temperature display Target supply air temperature Mode button Selection of use mode...

Page 6: ...ntilation unit runs normally in the Home mode To select 1 Press the Mode button to scroll to mode 2 The ventilation system adjusts itself to the new setting Home mode with boosted ventilation 3 When e...

Page 7: ...w the system to make slight changes to the defined temperature and ventilation values to save energy In Eco mode the system will not react to temperature changes as quickly as in normal mode but waits...

Page 8: ...you increase the risk of ice build up in your ventilation unit This risk is higher during extreme freezing out conditions and with high indoor humidity extensive shower use and lots of drying laundry...

Page 9: ...C TE45 ESW only Other models show 0 12 r7 Pre heated outside air temperature CHG AGH electrical pre heater C TE02 Only if equipped with CHG AGH or electrical pre heater 32 r8 Relative humidity of extr...

Page 10: ...supply air Ventilation is not sufficient If the ventilation is not sufficient 1 Make sure the filters are clean and do not need to be replaced If the filters are dirty replace them as instructed in c...

Page 11: ...The error code is visible in the display All units are stopped AB fault tolerant The error code flashes in the display in 2 second intervals The exhaust fan runs in minimum speed Service Text FILS is...

Page 12: ...der prompt FILS when the service period has expired Acknowledge the FILS service reminder after maintenance by pressing any button on the eWind operating panel for 5 seconds NOTE When performing a mai...

Page 13: ...e is switched off NOTE For LTR series units The power cuts off when the service hatch is opened 1 Open the service hatch 2 Remove the filter from the ventilation device 3 Remove the filter fabric from...

Page 14: ...angers NOTE Visit the HelpCenter on our webpage www enervent fi for videos showing the maintenance tasks To replace DANGER DANGER Turn off the ventilation unit by switching off the main power supply b...

Page 15: ...ating the exchanger Leave the holders on the heat exchanger 8 Loosen the U beam on one side of the heat exchanger by removing the screws under the U beam rubber gasket 9 Unscrew the hexagonal screw of...

Page 16: ...d Restart the pump Replace the motor or the belt Replace the actuator Find out why replace the fan The unit will not start before the alarm condition has been removed and the alarm acknowledged by pre...

Page 17: ...nit service hatch is open Close the service hatch TE30 temperature sensor is faulty Repair or change the sensor AL7 Supply air hot Fire hazard 55 C Supply air hot Fire hazard Check for any heat source...

Page 18: ...18...

Page 19: ...19 User instructions EN...

Page 20: ...sto com www enervent com Enervent eWind ECO C 3 sec 120 min Quick guide for user ENG Acknowledge the FILS service reminder after maintenance by pressing any button on the eWind operating panel for 5 s...

Reviews: