9
Bentone BFG1
Measurements according to EN 3746: 2010
Alt.1 The sound level of the burner can be reduced by equipping the burner
with silencer. Installation must be done so it does not prevent air supply
to the burner.
Alt.2 The burner’s noise level can be reduced by connecting the burner’s air
intake to the air duct that opens into an appropriate location. Installation
must be done so it does not prevent air supply to the burner.
2.3.1 Gas categories, approved gases
Only dry gas is permitted for use
Gerätekategorien
appliance categories
Versorgungsdrücke
supply pressures
Bestimmungsländer
countries of destination
Bermerkungen
remarks
II2H3B/P
20:30/360 mbar
AT,CH,CZ,DK,EE,FI,GR,HU
IS,IT,LT,NO,SE,SK,SI,TR
II2E3B/P
20:30/360 mbar
LU,PL
II2H3P
20:30/360 mbar
ES,GB,IE,PT
II2ELL3B/P
20:25:30/360 mbar
DE
II2Er3P
25:30/360 mbar
FR
II2L3B/P
25:30/360 mbar
NL
II2E(R)I3P
20:30/360 mbar
BE
I3B/P
30/360 mbar
CY,MT
II2R3R
20:30/360 mbar
FOR ALL OTHER COUNTRIES
Burner correspond to IP20
2.3.2 Electric Specification
EN 60335-2-102
Type
BFG1
Motor
110W 0,9A 230V 50Hz 4µF
The recommended main fuse
motor
6,3 A
Control power
1N230V 0,8A 50Hz IP 20
Sound
79 dBA ± 0,5 dBA